Rx power and the link budget
Receive power is the one DDM value that is almost always real, and it is the end of a simple equation: what the far end launched minus what the path lost. Read both ends and you have the measured loss of the link; compare it with what the plant should lose and you know whether the fibre, the connectors or the module is the problem — and how much margin is left before the link fails.
The equation
Rx(here) = Tx(far end) − loss(path)
loss(path) = fibre attenuation × length + Σ connectors + Σ splices + Σ passive components
margin = Rx(here) − sensitivity(this receiver)
Both Tx and Rx come from DDM (Parameters); the loss elements come from the plant record or from these typical figures:
| Element | Typical loss | Notes |
|---|---|---|
| SMF at 1310 nm | 0.32–0.35 dB/km | G.652 |
| SMF at 1550 nm | 0.18–0.22 dB/km | — |
| SMF at 1610 nm (CWDM edge) | 0.22–0.25 dB/km | water peak at 1383 nm is 0.3–0.5 dB/km on old fibre |
| MMF at 850 nm | 2.5–3.5 dB/km | OM3/OM4 |
| Connector pair (LC/SC, UPC or APC) | 0.2–0.5 dB (0.75 max per TIA) | dirty: +0.5 … +3 dB or more |
| MPO/MTP pair | 0.35–0.75 dB | polarity and pinning matter more than loss |
| Fusion splice | 0.05–0.1 dB | — |
| Mechanical splice | 0.2–0.5 dB | — |
| CWDM mux + demux (per channel) | 2.5–4 dB total | plus 1–2 dB per pass-through band |
| DWDM mux/demux (AWG) | 3–6 dB per pair | — |
| PON splitter 1:2 / 1:4 / 1:8 | ≈ 3.5 / 7.2 / 10.5 dB | — |
| PON splitter 1:16 / 1:32 / 1:64 | ≈ 13.7 / 17.2 / 20.5 dB | — |
| Inline attenuator | as labelled ±0.5 dB | — |
Detailed budget method for CWDM: Mux/demux & link budget; unit conversions: Units & conversions.
Worked example: 10GBASE-LR, 12 km
- Far-end Tx (DDM): −2.5 dBm
- Expected loss: 12 km × 0.35 = 4.2 dB + 4 connector pairs × 0.4 = 1.6 dB + 6 splices × 0.1 = 0.6 dB → 6.4 dB
- Expected Rx: −2.5 − 6.4 = −8.9 dBm
- Sensitivity (10GBASE-LR, average): about −14.4 dBm → expected margin ≈ 5.5 dB
| Measured Rx | Interpretation |
|---|---|
| −8 … −10 dBm | as designed |
| −12 dBm | 3 dB missing — one dirty or damaged connector, a macro-bend, or a splice; clean and inspect, then OTDR |
| −14 dBm | at the sensitivity limit — link may be up but with errors and flaps |
| −40 dBm | no light — fibre, wrong port, Tx off at the far end (No link checklist) |
| −3 dBm | far end launching more than expected, or a much shorter path than recorded |
Both directions
Measure A→B and B→A. Fibre loss is symmetric to within a few tenths of a dB; a difference larger than the DDM accuracy (±3 dB, in practice > 2 dB) means the asymmetry is at an end, not in the path:
| Observation | Meaning |
|---|---|
| Both directions low by the same amount | shared path: length, splices, a mux, dirty connectors in both fibres |
| One direction low | dirty/damaged connector on that fibre, weak Tx on the sending side, wavelength mismatch for that direction (BiDi/CWDM) |
| One direction dark | broken fibre of the pair, Tx disabled or dead, Tx/Rx crossed |
| Both fine, errors anyway | not a power problem — dispersion, FEC, polarity on parallel optics (VDM & FEC) |
Per-lane on parallel optics: compare the four or eight Rx values with each other before comparing with a specification (Per-lane diagnostics).
Overload: too much light
Every receiver has a maximum input; above it the photodiode or TIA saturates and errors appear even though "the signal is strong". Typical overload points: −1 … 0 dBm for 10G SR/LR PIN receivers, −3 dBm for 1G, −7 … −9 dBm for APD receivers in ZR/DWDM modules, +2 … +4 dBm for PAM4. A long-reach module on a short link needs an attenuator: size it so that Rx lands in the middle of the window (Typical values, Receivers).
Power is not everything: dispersion and penalties
IEEE budgets reserve several dB for penalties — dispersion, reflections, jitter — that do not show up as lost power. For 10GBASE-LR the budget is 9.4 dB of which only 6.2 dB is channel insertion loss; the rest is penalty allocation. So a link can show "3 dB of margin" by Rx power and still be at its limit on a long span at 1550 nm, on CWDM 1610 nm, or on OM1 fibre at 10G. Symptoms are errors and flaps with good levels (Link flapping); the cure is a dispersion-tolerant module (EML, shorter reach, lower rate) rather than more power.
Margin policy
| Margin (Rx − sensitivity) | Verdict |
|---|---|
| > 6 dB | healthy; room for ageing and one dirty connector |
| 3–6 dB | acceptable; monitor and keep a baseline |
| 1–3 dB | marginal; expect flaps on hot days or after any handling |
| < 1 dB | fix now — clean, re-splice, shorten, or change reach class |
Design new links for at least 3 dB of margin after ageing (0.5–1 dB for laser ageing over life, 0.5 dB per future repair splice).
Recording
Record Tx and Rx at both ends at installation — the link passport (Monitoring). Later readings are then deltas, which are immune to the ±3 dB absolute accuracy of DDM (Accuracy & limits).
In CodingBox
The DDM screen shows Tx and Rx with the module's own thresholds and logs them over time; reading both modules of a link on the bench before installation gives the launch powers for the budget above. For a module pulled from a failed link, the logged Rx history shows whether the loss grew slowly (plant) or the module's Tx fell (Tx bias & laser ageing).
Budgets with splitters and class windows: ODN classes & PON budget. Amplified links where noise, not power, is the limit: Amplification & OSNR.
Design-side detail — allowances by standard, penalties, margin policy and four worked budgets: Link budget engineering; measuring the plant loss with LSPM and OTDR instead of inferring it from DDM: Testing and measurement.