CodingBox เอกสารประกอบ

ข้อกำหนดฮาร์ดแวร์ตระกูล SFP (INF-8074, SFF-8431…)

The SFP footprint is shared by SFP, SFP+, SFP28 and SFP56, but the documents that define it were written in layers over twenty years. Knowing which layer defines what explains why two modules that look identical behave differently in the same port.

The original MSA

INF-8074 — SFP Transceiver (1.0). The founding SFP agreement: the 20-pin card-edge interface, module outline, the low-speed control signals (TX_DISABLE, TX_FAULT, RX_LOS, MOD_DEF/module-present) and the two-wire identity memory that later became SFF-8472.

Electrical layer (SFP+)

DocumentWhat it defines
SFF-8431 — 10 Gb/s and Low Speed Electrical Interface (4.1)the SFI high-speed interface, linear vs limiting modules, and the low-speed signalling
SFF-8418 — 10 Gb/s Electrical Interface (1.4)high-speed electrical detail split out of 8431
SFF-8419 — Power and Low Speed Interface (1.3)supply rails, power classes, low-speed pin behaviour
SFF-8461 — Active Cable Specifications (0.2)active copper/optical cables and their test methods

Mechanical layer

DocumentWhat it defines
SFF-8432 — Module and Cage (5.2a)the module and host cage outline used by all SFP-class modules
SFF-8071 — 0.8 mm Card Edge Connector (1.9a)the 20-pin connector
SFF-8433 — Ganged Cage Footprints and Bezel Openings (0.7)multi-port cages on a host board
SFF-8075 — PCI Card Version of SFP Cage (1.0)cages on PCI adapters

"Transceiver solution" documents by rate

Each bundles the mechanical and electrical requirements for one rate class:

DocumentClassRate
SFF-8084 (1.7)4 Gb/s4GFC
SFF-8083 (3.1)SFP1010G
SFF-8081 (1.4)SFP1616GFC
SFF-8402 (1.1)SFP2825G / 32GFC

SFP56 (50G PAM4) builds on the SFP28 definition with the IEEE 802.3cd electrical interface; see SFP56.

Management layer

  • SFF-8472 — identity, diagnostics, thresholds (details).
  • SFF-8079 / SFF-8089 — rate and application selection and codes (details).
  • SFF-8690 — tunable DWDM memory map (details).

Why it matters for coding

Memory fields that CodingBox edits — rate codes, power class, linear/limiting flag, compliance codes — each trace back to one of these documents. When a recoded module does not link, check that what the identity bytes claim (per SFF-8472/8089) matches what the hardware layer actually is (per SFF-8431/8419): a module coded as a power class or interface type it cannot deliver is refused or held in low power by the host.

The electrical dialects on the SFP high-speed pins — 1000BASE-X vs SGMII at 1G, SFI at 10G, 25GAUI at 25G: SGMII & serial gigabit, XGMII, XAUI and the AUI family.