CodingBox دستاویزات

InfiniBand کی رفتاریں

InfiniBand names each generation with a short code. The code is a per-lane rate; the port bandwidth is that rate times the link width (usually ×4).

Generations (per lane)

GenerationPer lane×4 port
SDR2.5 Gb/s10 Gb/s
DDR5 Gb/s20 Gb/s
QDR10 Gb/s40 Gb/s
FDR~14 Gb/s~56 Gb/s
EDR25 Gb/s100 Gb/s
HDR50 Gb/s200 Gb/s
NDR100 Gb/s400 Gb/s

Modules

Because the common port is ×4, InfiniBand rides QSFP-family optics: EDR on QSFP28, HDR on QSFP56, and NDR on OSFP or QSFP112. The form factor follows the per-lane rate and lane count, just as it does for Ethernet.

Early generations (SDR–QDR) used 8b/10b line coding; FDR and later moved to 64b/66b, which is why FDR's per-lane figure is about 14 rather than 12.