控制器與固件:DDM、APC、記憶體與保護功能
Every managed transceiver has a small computer inside. The microcontroller (MCU) measures, regulates, reports and — from the programmer's point of view most importantly — is the memory you read and write. Whether a module has a plain EEPROM or an MCU pretending to be one decides how it can be coded, why some writes vanish after a power cycle and why passwords exist at all. This page describes what the controller does and how its design shows up on the bench.
What the MCU does
| Task | Details | Visible as |
|---|---|---|
| Measurement | samples temperature (thermistor or on-chip sensor), Vcc, laser bias, monitor-PD current (Tx) and receiver photocurrent (Rx) through a 10–12-bit ADC several times per second; applies factory calibration | DDM values — Parameters |
| APC — automatic power control | compares monitor-PD current with the factory target and adjusts the driver's bias DAC | constant Tx power, rising bias — Tx bias & ageing |
| Temperature compensation | look-up tables adjust modulation current and, on PAM4, DSP settings across temperature | stable extinction ratio |
| TEC control | PID loop holding laser temperature on cooled modules; wavelength-locker feedback on DWDM | laser temperature, TEC current monitors |
| Thresholds and flags | compares every monitor with the alarm/warning thresholds, sets latched flags, drives IntL | Thresholds & alarms |
| Low-speed pins | reads TX_DISABLE, RS0/RS1, LPMode, ResetL; drives TX_FAULT, RX_LOS (or gates the hardware signals) | pin behaviour |
| Two-wire slave | answers at A0h/A2h (SFP) or A0h with pages/banks (QSFP, CMIS) | the memory map — Two-wire interface |
| State machines | CMIS module and data-path states; application selection; squelch | CMIS |
| Protection and vendor functions | passwords, write-protect regions, save commands, vendor unlock, authentication signatures | Write-protection types |
| CDB / firmware update | on CMIS modules, receives and flashes new firmware images | firmware version bytes |
Typical parts: 8-bit MCUs (8051-class) with a few kB of flash in low-cost SFP/SFP+; 32-bit Cortex-M class in 100G+ and CMIS modules; some vendors use a dedicated transceiver-controller ASIC that integrates ADCs, DACs and the two-wire slave.
Two ways to build the memory
| Design | How the map is stored | Consequences for programming |
|---|---|---|
| Discrete EEPROM (e.g. AT24C02-class) for A0h, MCU for A2h | A0h identity is a real serial EEPROM the host and programmer talk to directly; the MCU handles diagnostics only | A0h writes are plain EEPROM writes — respect t_WR and page size; a hardware WP pin may block them (Write-protection types 1–3) |
| MCU-emulated map | the MCU answers every two-wire request from RAM and mirrors changes to its internal flash/EEPROM — or not | writes go where the firmware decides: accepted, ignored, password-gated, stored only after a save command, or overwritten from the firmware's own copy on the next boot (types 4–5) |
| Hybrid | EEPROM for the vendor block, MCU for pages and passwords | mixed rules per byte range |
An emulated map explains most bench mysteries: FFh from a page the firmware does not implement, writes that "succeed" and revert, bytes that are read-only in one range and free in the next, clock stretching while the MCU is busy sampling (EEPROM read & write errors).
Boot and the t_init window
On power-up the MCU loads calibration and identity from its non-volatile store, starts the ADC, runs the APC to its target and only then enables the two-wire slave and clears data-not-ready. That is the 300 ms (SFP) to 2 s (QSFP/CMIS) the specifications allow before a host may expect answers, and the reason a read immediately after insertion returns garbage (What the host does).
Calibration lives here
The raw ADC counts mean nothing without the constants the factory measured on a test station: monitor-PD current vs actual launch power, receiver photocurrent vs input power at the module's wavelength, thermistor curve, bias DAC scale. On internally calibrated modules the firmware applies them and reports physical units; on externally calibrated modules the constants are written to A2h 56–91 for the host to apply (Calibration). Overwriting the vendor area where some firmwares keep these constants produces absurd DDM or a dead APC loop — the classic way a careless write "bricks" a module (Manufacturing & testing).
How protection is implemented
| Mechanism | Implementation | Bench view |
|---|---|---|
| Password | firmware compares the 4 bytes written to the password area (SFP A2h 123–126, QSFP 123–126, CMIS 122–125) with a stored value; unlocks writes for the session | WRITE FAIL until the right value is entered — Passwords |
| Write-protect regions | firmware ignores writes to ranges it considers read-only (checksums, thresholds, calibration, vendor area) | bytes read back unchanged, no error |
| Hardware WP pin on a discrete EEPROM | the pin is tied high inside the module or driven by the MCU | needs the programmer board to drive it |
| Save command | writes land in RAM; a vendor-specific sequence commits them to flash | reverts after power cycle unless the sequence is sent |
| Firmware mirror | on boot the firmware rewrites the map from its own image | changes vanish at every power cycle — only the vendor's tool can change the image |
| Authentication | the firmware computes a signature (hash of serial, vendor data and a secret) into vendor bytes; the host verifies | identity edits pass checksums yet the host still rejects — Vendor lock |
How each type is recognised and programmed: Write-protection types, EEPROM recoding.
Firmware updates
CMIS modules can receive firmware over the two-wire bus through CDB commands (start download, write blocks, complete, run, commit), often with two image banks so a failed update falls back. SFF-8472/8636 modules have no standard mechanism; vendors use proprietary sequences through vendor bytes. Firmware fixes are how vendors resolve CMIS interoperability problems (CMIS issues), and firmware version bytes (CMIS lower page 39–40, page 01h 128–129) are worth recording with the identity.
Failure modes of the controller
| Symptom | Likely cause |
|---|---|
| Module invisible on the bus, optics otherwise fine | MCU not booting: corrupted firmware, brown-out, damaged crystal |
| DDM values frozen or absurd | ADC or calibration corruption; firmware hang |
| Tx power drifting although APC should hold it | monitor-PD or ADC fault, APC disabled |
| Random NACKs, slow reads | MCU overloaded (sampling), clock-stretch limits exceeded by a fast programmer |
| Works, but every write reverts | firmware mirror by design — not a fault |
| Module dead after a write | firmware configuration or calibration area overwritten |
In CodingBox
CodingBox treats the module as the firmware presents it: it detects the map type, applies known passwords and programming scripts for save-command and mirrored designs, recalculates checksums, keeps a backup before every write and lets you restore it from the code database if a controller reacts badly. The EEPROM editor marks ranges that the specification defines as read-only or vendor-specific so you know when you are writing into the firmware's private territory.