በተለያዩ አቅራቢዎች የፖርት ስያሜ እና LED መብራቶች
"Put the module in Et33/1" means nothing on a Juniper and "xe-0/0/48" nothing on a Nexus; the same physical cage has a different name in every network OS, and breakout children, stack members and line cards add their own notation. The LEDs next to the cage are a second language: green, amber, blinking, off — with vendor-specific meanings. This page gives the naming grammar per NOS, the slot/port semantics behind it, the breakout and management-interface conventions, the LED codes, and the commands that make a port blink so you can find it in a rack.
Naming grammar by NOS
| NOS | Pattern | Examples | Read as |
|---|
| Cisco IOS / IOS-XE | <Type><switch>/<module>/<port> | GigabitEthernet1/0/1, TenGigabitEthernet1/1/1, TwentyFiveGigE1/0/25, FortyGigabitEthernet1/1/1, HundredGigE1/0/49, Gi1/0/1 (short) | switch (stack member) / module (0 = built-in, 1 = uplink module) / port |
| Cisco NX-OS | Ethernet<slot>/<port>[/<sub>] | Ethernet1/1, Eth1/49/1 (breakout child) | slot (1 on fixed) / port / breakout lane |
| Cisco IOS-XR | <Type><rack>/<slot>/<instance>/<port>[/<sub>] | HundredGigE0/0/0/0, FourHundredGigE0/0/0/12, TenGigE0/0/0/0/1 (breakout) | rack / slot / instance (subslot) / port |
| Arista EOS | Ethernet<port>[/<lane>] | Ethernet1, Ethernet33/1…33/4 (breakout children), Et49/1 | port / lane; a QSFP port without breakout is Et33/1 |
| Juniper Junos | <media>-<fpc>/<pic>/<port>[:<channel>] | ge-0/0/0, xe-0/0/48, et-0/0/50, et-0/0/50:1 (breakout), mge- (multigig), fte- (40G on EX4300) | media (ge 1G, xe 10G, et 25G+) - FPC (stack member/line card) / PIC (module) / port |
| Huawei VRP | <Type><chassis>/<slot>/<port> | GigabitEthernet0/0/1, XGigabitEthernet0/0/1, 25GE1/0/1, 100GE1/0/1, 100GE1/0/1:1 (breakout) | chassis / slot / port |
| H3C Comware | <Type><chassis>/<slot>/<port> | GigabitEthernet1/0/1, Ten-GigabitEthernet1/0/49, Twenty-FiveGigE1/0/1, HundredGigE1/0/53:1 | as VRP |
| HPE Aruba AOS-CX | <member>/<slot>/<port> | 1/1/1, 1/1/49:1 (breakout) | member / slot / port |
| HPE Aruba AOS-S (ProCurve) | <port> or <letter><port> | 1, A1, 49 | flat; letters for modules |
| Dell OS10 | ethernet<node>/<slot>/<port>[:<sub>] | ethernet1/1/1, ethernet1/1/49:1 | node / slot / port : breakout |
| Extreme EXOS | <slot>:<port> | 1:1, 2:49 | slot (stack member) : port |
| Ruckus ICX | <unit>/<slot>/<port> | 1/1/1, 1/2/1 (uplink module) | unit / slot / port |
| Brocade FOS | <slot>/<port> or port index | 0, 1/3 | index 0-based on fixed switches |
| SONiC | Ethernet<lane-index> | Ethernet0, Ethernet4, Ethernet8… (4-lane platform), Ethernet0…Ethernet3 after 4× breakout; 8-lane: Ethernet0, Ethernet8, Ethernet16 | first lane index, not port number; aliases like Eth1/1 or etp1 exist per platform |
| Cumulus / NVUE | swp<port>[s<lane>] | swp1, swp32, swp32s0…swp32s3 (breakout), eth0 (mgmt) | switch port / sub-port |
| MikroTik RouterOS | <type>-<n> | ether1, sfp-sfpplus1, sfp28-1, qsfp28-1-1…-1-4 (lanes) | type - number - lane |
| Ubiquiti | <port> in UI, eth<n> inside | Port 49, eth48 | 0-based inside |
| Nvidia Onyx (MLNX-OS) | Eth<slot>/<port>[/<sub>] | Eth1/1, Eth1/1/1 | — |
| Linux hosts | eth<n>, ens<n>f<n>, enp<bus>s<slot>f<fn> | enp94s0f1, ens3f0np0 | predictable names from PCIe address (NIC tools) |
Slot, module, port: what the numbers mean
| Number | On a fixed switch | On a stack | On a chassis |
|---|
| First (switch / chassis / FPC / member / node) | 1 (or 0 on Juniper/Huawei) | stack member ID 1–8 | line-card slot (Juniper FPC) or chassis number |
| Second (module / slot / PIC) | 0 = built-in ports, 1 = uplink module (Cisco), or 0 always | same | subslot/PIC on a card |
| Third (port) | front-panel number, 1-based (0-based on Juniper, SONiC, FOS) | — | — |
| Fourth (sub / lane / channel) | breakout child 1–4 or 0–3, or 1–8 | — | — |
Port numbering on the faceplate is usually left-to-right, top row odd and bottom row even (1/2, 3/4…) on dual-row copper blocks, and left-to-right sequential on SFP rows — check the silkscreen, not the assumption.
Breakout children
| NOS | Parent | Children | Enabling command |
|---|
| NX-OS | Ethernet1/49 | Ethernet1/49/1–/4 | interface breakout module 1 port 49 map 25g-4x |
| Arista | Ethernet49/1 | Ethernet49/1–49/4 | speed on children / hardware port-group |
| Junos | et-0/0/48 | et-0/0/48:0–:3 | set chassis fpc 0 pic 0 port 48 channel-speed 25g |
| IOS-XR | HundredGigE0/0/0/0 | TwentyFiveGigE0/0/0/0/0–/3 | controller Optics … breakout 4x25 |
| Huawei | 100GE1/0/1 | 25GE1/0/1:1–:4 | port split dimension … |
| Dell OS10 | ethernet1/1/1 | ethernet1/1/1:1–:4 | interface breakout 1/1/1 map 25g-4x |
| SONiC | Ethernet0 | Ethernet0, Ethernet1, Ethernet2, Ethernet3 | config interface breakout Ethernet0 4x25G |
| Cumulus | swp1 | swp1s0–s3 | nv set interface swp1 link breakout 4x25G |
| MikroTik | qsfp28-1-1 | qsfp28-1-1…-1-4 always present | speed per lane |
Commands in context: Port configuration recipes; cabling: Breakout & MPO.
Management and special interfaces
| Interface | Names |
|---|
| Out-of-band Ethernet | mgmt0 (NX-OS), GigabitEthernet0/0 (IOS-XE), MgmtEth0/RP0/CPU0/0 (XR), Management1 (EOS), me0/em0/fxp0/vme (Junos), MEth0/0/1 (Huawei), M-GigabitEthernet0/0/0 (H3C), mgmt (AOS-CX), eth0 (SONiC, Cumulus), ether1 often (MikroTik) |
| Console | con0, console |
| Loopback / SVI / VLAN | Loopback0, Vlan10, irb.10 (Junos), Vlanif10 (Huawei) |
| LAG | Port-channel1 (Cisco), ae0 (Junos), Eth-Trunk1 (Huawei), Bridge-Aggregation1 (H3C), lag 1 (AOS-CX), port-channel1 (OS10), PortChannel0001 (SONiC), bond0 (Cumulus) (Forwarding basics) |
| Stack / VC ports | vcp-255/0/50 (Junos), StackPort1/1 (Cisco), stack-port 1/1 (Stacking & MLAG) |
LEDs
| LED | State | Usual meaning | Vendor variations |
|---|
| Port link | off | no link, port shut, or module not accepted | — |
| Port link | solid green | link up at top speed | Cisco: green = link; Arista: green |
| Port link | blinking green | link up with traffic | most |
| Port link | solid amber / orange | link at lower speed (1G in a 10G port), or errdisabled/blocked | Cisco IOS: amber = disabled/errdisable; Juniper: amber = duplex/half or fault; Aruba: orange = reduced speed |
| Port link | blinking amber | errdisable, PoE fault, or STP blocking | Cisco |
| Port link | alternating green/amber | link fault / diagnostics | some |
| QSFP-DD / OSFP port LEDs (2 or 4 per cage) | per-child status after breakout | one LED per breakout child on many platforms | Arista, Cisco N9K |
| Module status LED | amber | module unsupported/invalid | Nexus, some Juniper |
| Speed LED (separate, when present) | off / green / amber | 1G / 10G / 25G etc. per mode button | Cisco Catalyst "mode" button toggles port LEDs between STAT, SPEED, DUPLEX, STACK, PoE |
| System / status | green / amber / red | OK / warning (fan, temperature) / fault | — |
| Stack / master | solid / blinking | active member / stack master | Cisco, Extreme |
| PSU / fan | green / amber / off | OK / failed / absent | — |
| Beacon / locator | blue blinking | identifies the chassis | hw-module beacon, system beacon |
LED codes are in each platform's hardware installation guide; the "mode" button on Catalyst-class switches changes what the port LEDs show, which is a classic source of misread states.
Finding a port physically
| NOS | Command |
|---|
| Cisco NX-OS | locator-led interface ethernet 1/1 |
| Cisco IOS-XE | hw-module beacon slot 1 on (chassis), port LED by mode button |
| Arista | locator-led interface Ethernet1 on / show locator-led |
| Junos | request chassis beacon fpc 0 port 5 pic 0 on |
| Huawei | display device + physical labels; beacon on chassis |
| Dell OS10 | beacon enable ethernet 1/1/1 (platform-dependent) |
| SONiC | sfputil show presence; platform-specific LED control |
| Linux host | ethtool -p eth0 10 (blink 10 s) |
In CodingBox