የCWDM ዝርጋታ እና መላ መፈለግ
CWDM is the simplest way to multiply a fibre, and most of its failures are simple too — once you know where to look. This page covers the common topologies and the faults that recur in the field.
Topologies
- Point-to-point — one mux pair, 4–18 channels over one fibre pair (or one fibre with BiDi channel pairs). The default for connecting two sites.
- Ring with OADMs — a fibre ring where each site drops and adds its own channel with an OADM; the rest pass through. Loss accumulates through every OADM, so the budget must be computed end-to-end for the farthest channel.
- Hybrid with a grey pass-through — the mux has a 1310 (or 1550) port so an existing non-WDM link keeps working on the same fibre while CWDM channels are added.
- Mixed rates — 1G and 10G channels coexist freely on one mux; each channel is independent.
Design checklist
- Choose a channel plan both ends share; avoid the water-peak channels on legacy fibre (channel plan).
- Compute the link budget per channel, worst band first (mux/demux & link budget).
- Put the longest spans on the 1470–1610 nm channels.
- Check 10G dispersion beyond ~60–80 km.
- Label everything by wavelength; record the installation Rx power per channel.
Recurring faults
| Symptom | Cause | Check |
|---|---|---|
| One channel down, others fine | module in the wrong mux port, or wrong-wavelength module | read the module's wavelength field; match it to the port label |
| Channel works on short link, fails on long | budget miss on that band (O-band loss, water peak) | recompute budget with the real band loss; move to a 1550-band channel |
| All channels down | fibre cut, or mux/demux swapped ends / mismatched plans | OTDR; verify both muxes use the same plan |
| 10G channel errors, 1G on same mux fine | chromatic dispersion at 10G on the upper band | shorten, use a dispersion-tolerant module, or DWDM/coherent |
| Rx power drifting down over months | dirty connector at the mux, ageing laser | clean; compare Tx bias trend (failures) |
| Module rejected by the switch | vendor lock | code identity (vendor lock) |
Diagnostic sequence
Follow the standard ladder — levels → clean → swap → OTDR — with one CWDM-specific step first: confirm the module's wavelength matches the mux port. A surprising share of "dead channel" tickets is a 1531 module in a 1551 port.
In CodingBox
Before installation, read every CWDM module: the Check transceiver screen shows its wavelength and reach class, and the DDM screen its Tx power — the inputs to the budget and the labels for the mux. After installation, compare the far-end Rx power with the budget; the difference is your real margin.