CWDM চ্যানেল প্ল্যান
The CWDM grid (ITU-T G.694.2) defines 18 wavelengths spaced 20 nm apart, from 1271 nm to 1611 nm. Each is a channel a coloured transceiver can occupy.
The 18 wavelengths (nm)
1271 1291 1311 1331 1351 1371 1391 1411
1431 1451 1471 1491 1511 1531 1551 1571
1591 1611
What gets used in practice
- The eight wavelengths 1471–1611 nm are the most common, because they sit away from the fibre's high-loss "water peak" region around 1383 nm and outside the O-band used by other services.
- Systems are sold as 4-, 8- or up to 18-channel muxes.
- Band context and the other WDM grids: Wavelength bands & channel plans.
Colours
Each wavelength has a conventional colour so field engineers can match a transceiver to its mux port by sight. The module still reports its exact wavelength in memory.
In CodingBox the wavelength field appears on the Check transceiver screen — a quick way to verify a coloured CWDM module without reading the label.