CodingBox مستندات

ماژول‌های نوری و کابل‌های InfiniBand

InfiniBand uses the same pluggable housings as high-speed Ethernet, but the choice of cable versus transceiver — and the tolerance for third-party modules — follows its own rules shaped by HPC and AI clusters.

Cable or transceiver, by generation

GenerationPortCopper DACActive optical cableTransceiver + fibre
EDR 100GQSFP28up to ~3–5 mup to 100 mSR4 (MPO-12 MMF), LR4
HDR 200GQSFP56up to ~2 mup to 100 mSR4/DR4
NDR 400GOSFP (twin-port 2×400G)~1–2 mlimitedDR4/DR8 on MPO-12 APC single-mode

The pattern: as rates rise, passive copper reach collapses and fabrics move to optics. At NDR the norm is single-mode DR optics with MPO-12 APC connectors — the angled polish is mandatory, and mixing APC with flat UPC connectors is a common installation fault.

Twin-port OSFP

NDR switch ports are commonly twin-port OSFP: one OSFP module carries two independent 400G links (2×DR4), doubling faceplate density. A finned integrated heat sink handles the power. See OSFP.

Signalling and FEC

  • EDR: NRZ 25G lanes; HDR: PAM4 50G; NDR: PAM4 100G.
  • RS-FEC is mandatory from HDR onward. FEC mismatch or a module that does not advertise the expected FEC is a frequent "link never trains" cause.

Vendor policy

InfiniBand fabrics are dominated by a single switch/NIC vendor, and that vendor's platforms validate cables and optics by identity. A module that is not recognised may read correctly yet fail to link with a status such as "speed and type: Not supported" — see Vendor lock. Operators therefore stock qualified optics and, where third-party modules are used, code them to the expected identity.

Operating at scale

  • Thousands of optics per cluster: even a small annual failure rate means a steady stream of replacements. Track per-lane DDM to catch a dying lane before it slows a collective operation.
  • Cleanliness on MPO end-faces is the dominant cause of flaps — see CMIS issues for 400G specifics.

In CodingBox

CodingBox reads EDR/HDR modules per SFF-8636 and NDR OSFP/QSFP-DD per CMIS: identity, module state, per-lane DDM, and the identity fields that determine whether a fabric will accept the module.