CodingBox Documentation

DWDM system components

Unlike CWDM, a DWDM link is a system: coloured transmitters, precise filters, amplifiers and often dispersion management, all engineered together. Knowing the parts tells you what a pluggable DWDM transceiver is plugging into.

Where the coloured light comes from

ApproachWhat it isWhere used
Pluggable DWDM transceivera coloured SFP+/QSFP28/QSFP-DD in the router or switch itself"IP over DWDM", metro, DCI
Transpondera shelf card: grey client optic in, DWDM line optic outclassic transport systems
Muxpondera transponder that aggregates several clients (e.g. 10×10G) into one 100G+ wavelengthtransport, backbone

Pluggable DWDM optics — fixed or tunable — remove the transponder, which is why coding and tuning them from the host side matters.

Multiplexing

  • Mux/demux — thermally stabilised AWG (arrayed waveguide grating) or thin-film filters on the ITU grid, 40/48/96 channels; insertion loss ~4–7 dB.
  • OADM / ROADM — fixed or reconfigurable add/drop; a ROADM uses a wavelength- selective switch (WSS) so channels can be routed by software.
  • Interleaver — combines two 100 GHz grids offset by 50 GHz into one 50 GHz grid.

Amplification

DWDM's defining advantage is that all C-band channels can be amplified together by an EDFA (erbium-doped fibre amplifier):

AmplifierPositionRole
Booster (BA)after the muxraises launch power
In-line (LA)mid-span, every ~80–120 kmovercomes span loss
Pre-amplifier (PA)before the demuximproves receiver sensitivity

Each EDFA adds ~20–30 dB of gain and some noise; the accumulated noise sets the OSNR that ultimately limits reach (coherent & long-haul). Raman amplification (distributed, in the transmission fibre) extends spans further. L-band amplifiers double capacity on the same fibre.

Dispersion management

  • DCM (dispersion-compensating module) — a spool of DCF or a fibre Bragg grating that cancels chromatic dispersion for direct-detect 10G links beyond ~80 km.
  • EDC — electronic compensation inside a 10G module (limited).
  • Coherent — 100G+ receivers compensate dispersion digitally; no DCM needed.

Supervision

An optical supervisory channel (OSC) on a wavelength outside the amplified band (e.g. 1510 nm) carries management between amplifier sites. Optical channel monitors read per-channel power at the mux.

In CodingBox

Where the coloured source is a pluggable, CodingBox is the tool that touches it: it reads the module's channel/wavelength, its power and DDM, sets the channel on tunable modules through SFF-8690 / SFF-TA-1004, and codes identity for the host platform.

Amplifiers as infrastructure — types and numbers, placement on the line, the OSNR budget, operating rules and the choice against regeneration: Amplifiers & regeneration; transponders, ROADMs and protection switches as equipment classes: Transport & access equipment.