Storage protocols & optics
Several protocols move storage traffic, and each pairs with a family of optics.
The main protocols
| Protocol | Runs over | Typical optics |
|---|---|---|
| Fibre Channel | dedicated FC fabric | FC SFP+/SFP28 (SW/LW) |
| FCoE | lossless Ethernet | Ethernet 10/25G |
| iSCSI | TCP/IP Ethernet | Ethernet 10/25G |
| NVMe/TCP | TCP/IP Ethernet | Ethernet 25/100G |
| NVMe-oF (RoCE) | lossless Ethernet | Ethernet 25/100G |
| NVMe-oF (FC) | FC fabric | FC SFP28/QSFP |
FC vs Ethernet optics
- Fibre Channel modules are FC-rated and labelled SW (850 nm MMF) or LW (1310 nm SMF); rates are the GFC generations in Fibre Channel speeds.
- Ethernet storage uses standard Ethernet interfaces such as
25GBASE-SRor100GBASE-LR4(see Optical Ethernet interfaces).
NVMe over Fabrics
NVMe-oF carries the low-overhead NVMe protocol across a network — over Fibre Channel, over RoCE on lossless Ethernet, or over plain TCP — to reach flash arrays with minimal added latency.
A module built for one fabric reports rates and interfaces accordingly; CodingBox shows those fields so you can confirm a transceiver suits the storage network.