Transceiver na optiki za FC
Fibre Channel runs on the same pluggable form factors as Ethernet, but the optics are qualified to FC's own physical-layer standards and labelled with FC's own vocabulary. Picking — or coding — a module for a SAN means speaking that vocabulary.
Wave designations
| Label | Wavelength | Fibre | Typical reach |
|---|---|---|---|
| SW (short wave) | 850 nm | multi-mode OM3/OM4 | tens to ~150 m |
| LW (long wave) | 1310 nm | single-mode | 10 km |
| ELW (extended long wave) | 1550 nm | single-mode | 25–40 km |
Reach by generation (multi-mode)
Multi-mode reach shrinks as the rate rises — the reason SAN cabling moved from OM3 to OM4/OM5:
| Generation | OM3 | OM4 |
|---|---|---|
| 8GFC | 150 m | 190 m |
| 16GFC | 100 m | 125 m |
| 32GFC | 70 m | 100 m |
| 64GFC | 70 m | 100 m |
Long-wave optics on single-mode reach 10 km regardless of generation.
Standards behind the optics
The physical layer is defined by the T11 FC-PI series: FC-PI-5 (16GFC), FC-PI-6 (32GFC), FC-PI-7 (64GFC), FC-PI-8 (128GFC). Module identity, rates and DDM follow the same MSA management specs as Ethernet optics — SFF-8472 for SFP+/SFP28 and SFF-8636 for QSFP28 — with FC rates advertised through the rate and application codes.
Module by rate
| Rate | Module | Notes |
|---|---|---|
| 8GFC / 16GFC | SFP+ | 8b/10b → 64b/66b at 16GFC |
| 32GFC | SFP28 | same footprint as 25GbE optics |
| 64GFC | SFP-DD / SFP56-class | PAM4 |
| 128GFC | QSFP28 | 4 × 32GFC |
Vendor lock in SAN switches
FC switch vendors are among the strictest about optics. Platforms commonly validate the module's identity and show a port state such as Mod_Val (validating) or Mod_Inv (invalid) when a non-qualified module is inserted; the port will not come online. Storage arrays and HBAs also ship with qualified-parts lists. The mechanism is the same identity check as on Ethernet switches — see Vendor lock — and the remedy is the same: a module coded with the identity the platform expects.
DDM in a SAN
Because storage traffic is lossless, a marginal optical link shows up as CRC/invalid transmission words and credit stalls long before it shows as a down port. Trend Rx power and Tx bias on ISLs and array ports; a single lane degrading in a 128GFC QSFP28 is the classic silent fault (see Failures).
In CodingBox
CodingBox reads FC optics per SFF-8472/8636, decodes FC rate codes, shows DDM with thresholds, and recodes identity — vendor, part number, rate codes — for the SAN platform you target, with checksums recalculated and a backup in the code database.
Reading a SAN port's error counters and separating optics from congestion: FC port diagnostics; the login and zoning steps an optic must get a port through: FC protocol basics.