CodingBox 說明文件

FC 光模組

Fibre Channel runs on the same pluggable form factors as Ethernet, but the optics are qualified to FC's own physical-layer standards and labelled with FC's own vocabulary. Picking — or coding — a module for a SAN means speaking that vocabulary.

Wave designations

LabelWavelengthFibreTypical reach
SW (short wave)850 nmmulti-mode OM3/OM4tens to ~150 m
LW (long wave)1310 nmsingle-mode10 km
ELW (extended long wave)1550 nmsingle-mode25–40 km

Reach by generation (multi-mode)

Multi-mode reach shrinks as the rate rises — the reason SAN cabling moved from OM3 to OM4/OM5:

GenerationOM3OM4
8GFC150 m190 m
16GFC100 m125 m
32GFC70 m100 m
64GFC70 m100 m

Long-wave optics on single-mode reach 10 km regardless of generation.

Standards behind the optics

The physical layer is defined by the T11 FC-PI series: FC-PI-5 (16GFC), FC-PI-6 (32GFC), FC-PI-7 (64GFC), FC-PI-8 (128GFC). Module identity, rates and DDM follow the same MSA management specs as Ethernet optics — SFF-8472 for SFP+/SFP28 and SFF-8636 for QSFP28 — with FC rates advertised through the rate and application codes.

Module by rate

RateModuleNotes
8GFC / 16GFCSFP+8b/10b → 64b/66b at 16GFC
32GFCSFP28same footprint as 25GbE optics
64GFCSFP-DD / SFP56-classPAM4
128GFCQSFP284 × 32GFC

Vendor lock in SAN switches

FC switch vendors are among the strictest about optics. Platforms commonly validate the module's identity and show a port state such as Mod_Val (validating) or Mod_Inv (invalid) when a non-qualified module is inserted; the port will not come online. Storage arrays and HBAs also ship with qualified-parts lists. The mechanism is the same identity check as on Ethernet switches — see Vendor lock — and the remedy is the same: a module coded with the identity the platform expects.

DDM in a SAN

Because storage traffic is lossless, a marginal optical link shows up as CRC/invalid transmission words and credit stalls long before it shows as a down port. Trend Rx power and Tx bias on ISLs and array ports; a single lane degrading in a 128GFC QSFP28 is the classic silent fault (see Failures).

In CodingBox

CodingBox reads FC optics per SFF-8472/8636, decodes FC rate codes, shows DDM with thresholds, and recodes identity — vendor, part number, rate codes — for the SAN platform you target, with checksums recalculated and a backup in the code database.

Reading a SAN port's error counters and separating optics from congestion: FC port diagnostics; the login and zoning steps an optic must get a port through: FC protocol basics.