غیر خطی اثرات: SPM، XPM، FWM، بریلوئن اور رامن
Attenuation and dispersion are linear: doubling the power doubles the output and nothing else changes. Above a few milliwatts per channel in a 9 µm core, glass stops being linear — the refractive index starts to depend on intensity and the light starts to scatter off acoustic and molecular vibrations it excites itself. In a single 10G span this is invisible; in an amplified DWDM system with 80 channels over 1 000 km it sets the maximum launch power and therefore the reach. This page explains the five effects, when each matters, how they are quantified and how systems are designed around them.
Why fibre is non-linear at all
| Quantity | Value in G.652 | Meaning |
|---|
| Kerr coefficient n₂ | ≈ 2.6 × 10⁻²⁰ m²/W | index rises with intensity: n = n₀ + n₂·I |
| Effective area A_eff | ≈ 80 µm² (G.652), 110–150 µm² (G.654.E) | intensity = power ÷ area — a small core concentrates light |
| Non-linear coefficient γ = 2πn₂/(λ·A_eff) | ≈ 1.3 W⁻¹km⁻¹ (G.652 at 1550), ≈ 0.7 (G.654.E) | phase shift per watt per kilometre |
| Effective length L_eff = (1 − e^(−αL))/α | ≈ 20 km for a long span at 0.2 dB/km | the effects accumulate mostly in the first tens of kilometres after each amplifier |
| Typical launch power per channel | 0 … +3 dBm (1–2 mW) DWDM; up to +10 dBm single channel | non-linear phase φ_NL = γ·P·L_eff ≈ 0.03–0.3 rad per span |
The Kerr effects
| Effect | Mechanism | Symptom | Worst when |
|---|
| Self-phase modulation (SPM) | a pulse's own intensity changes its phase → chirp → spectral broadening; interacts with chromatic dispersion | eye closure, pulse distortion; in coherent systems a non-linear phase noise floor | high power, many spans, low dispersion |
| Cross-phase modulation (XPM) | neighbouring channels' intensity modulates a channel's phase | timing jitter and phase noise from other channels | dense spacing (50 GHz), low local dispersion, many channels |
| Four-wave mixing (FWM) | three frequencies generate a fourth at f₁ + f₂ − f₃; mixing products land on other channels | crosstalk that grows with power³ | D ≈ 0 (G.653 fibre), equal channel spacing, high power |
Local dispersion helps: it walks pulses of different channels past each other so XPM/FWM average out — the reason G.655 (small non-zero D) replaced G.653 for DWDM, and G.652 (D = 17) with dispersion compensation or coherent DSP is now preferred (Fibre types).
The scattering effects
| Effect | Mechanism | Threshold | Symptom | Where |
|---|
| Stimulated Brillouin scattering (SBS) | light generates an acoustic wave that reflects it backwards, shifted by ≈ 11 GHz | ≈ +6 … +10 dBm for a narrow-linewidth CW source in long SMF (lower for narrower lines) | forward power saturates, strong backward light, noise | CW lasers: 1550 nm analog video overlay (+17 dBm) and Raman pumps; mitigated by linewidth broadening / dithering (most transmitters do this) |
| Stimulated Raman scattering (SRS) | photons lose energy to molecular vibrations (Stokes shift ≈ 13 THz ≈ 100 nm) | total power above ≈ +20 … +25 dBm across a wide band | power tilt: short-wavelength channels pump long-wavelength ones — C-band feeds L-band | wide-band DWDM (C+L); managed by pre-emphasis and gain-tilt control; used deliberately in Raman amplifiers (Amplification & OSNR) |
Where non-linearity matters — and where it does not
| System | Non-linear penalty | Design response |
|---|
| Single 10G LR/ER span, −8 … +4 dBm | none | ignore |
| PON downstream +3 … +7 dBm, 20 km | none (SBS margin fine) | ignore; video overlay at +17 dBm uses SBS suppression |
| 10G DWDM, 40 ch, 8 × 80 km with EDFAs | XPM/FWM on G.655, SPM everywhere | launch −2 … +1 dBm/ch, dispersion map, unequal spacing on DSF |
| 100G/400G coherent DWDM, 80+ ch, 1 000+ km | non-linear phase noise limits OSNR gain from power | optimum launch ≈ 0 … +2 dBm/ch on G.652, +3 … +5 on G.654.E; GN-model planning |
| 400ZR pluggable, single span ≤ 120 km | small | launch −10 … 0 dBm; loss-limited |
| Submarine 10 000 km | dominant | G.654 large-A_eff fibre, low launch, many repeaters, C+L |
| Raman-amplified spans | pumps at +27 … +30 dBm | connector cleanliness and safety critical (Safety & handling) |
Rule: non-linear effects appear when power per channel × number of spans gets large; one span at moderate power never shows them.
Quantifying: the OSNR vs power trade-off
- OSNR improves 1 dB for every 1 dB of launch power (linear regime).
- Non-linear interference (NLI) noise grows with power³ — as +3 dB of noise per +1 dB of launch.
- The sum has an optimum: the non-linear threshold where linear ASE noise equals NLI; systems are planned 1–2 dB below it. The Gaussian-noise (GN) model estimates NLI from γ, D, span length, channel count and spacing; planning tools do this per route.
- Coherent DSP can partially undo SPM (digital back-propagation) but not XPM/FWM from other channels.
Mitigation summary
| Method | Targets | Used in |
|---|
| Keep launch power near optimum (0 … +3 dBm/ch) | all Kerr effects | every DWDM design |
| Non-zero local dispersion (G.652 / G.655 instead of G.653) | FWM, XPM | fibre choice |
| Dispersion management (DCM map) | SPM/XPM interaction | 10G DWDM |
| Large-effective-area fibre (G.654.E) | all (lower γ) | new long haul |
| Unequal channel spacing | FWM | DSF legacy routes |
| Linewidth dithering | SBS | CW analog, pumps |
| Gain tilt compensation, pre-emphasis | SRS | wide-band DWDM |
| Coherent DSP with NLC | SPM | 400G+ long haul |
| Distributed Raman amplification | (uses SRS) lowers launch power needed | ultra-long spans |
In CodingBox
Non-linear effects live in the line system, not in the module memory — but the module's declared Tx power and, for tunable DWDM modules, the channel plan are the inputs a planner needs. CodingBox shows the Tx power range and wavelength/channel fields so the per-channel launch budget starts from real numbers (Check transceiver, Tunable transceivers).