CodingBox دستاویزات

SFP

The Small Form-factor Pluggable (SFP) replaced the GBIC and became the most common optical module ever made. Its footprint is still used, unchanged, by SFP+, SFP28 and SFP56 — which is why a modern 50G port is physically the same size as a 1G port from two decades ago.

Key facts

Lanes × rate1 × up to ~4.25 Gb/s
Total1G class (also 2G/4G FC, OC-3/12/48)
ConnectorLC duplex (also simplex BiDi, RJ45 copper)
Supply3.3 V
Applications1000BASE-SX/LX/EX/ZX/BX, 1/2/4GFC, SONET/SDH, CWDM/DWDM SFP

Specifications

  • INF-8074SFP Transceiver 1.0: the original SFP MSA (mechanical, electrical).
  • SFF-8432SFP+ Module and Cage: the improved mechanical definition also used for SFP.
  • SFF-8472Management Interface: identification, DDM and thresholds.
  • SFF-8079SFP Rate and Application Selection; SFF-8089SFP Rate and Application Codes.
  • SFF-8075PCI Card Version of SFP Cage.

Management interface

SFP uses the two-address model of SFF-8472:

  • A0h — serial ID: vendor, part number, serial, transceiver codes, wavelength, distances, and the CC_BASE / CC_EXT checksums.
  • A2h — digital diagnostics: live monitors, alarm/warning thresholds, flags, and — on protected modules — the password area at offset 0x7B.

Not every 1G SFP implements A2h diagnostics; a capability bit in A0h says whether DDM is present.

Compatibility notes

  • Fits SFP+, SFP28 and SFP56 cages (rate permitting).
  • Coloured CWDM SFPs and DWDM SFPs use the same memory layout with the wavelength field set — see CWDM.

In CodingBox

Fully supported: read, decode, edit and write per SFF-8472 with automatic CC_BASE/CC_EXT recalculation in the EEPROM editor. Protected modules are handled through Protected memory & passwords.