XFP (10 Gigabit Small Form Factor Pluggable) was the first mainstream 10G module. It integrates the clock-and-data recovery inside the module and talks to the host over a clean serial XFI interface — which made it protocol-agnostic and host-friendly, but larger and hotter than the SFP+ that eventually displaced it.

Key facts

Lanes × rate1 × 9.95–11.3 Gb/s
Total10G
ConnectorLC duplex
Supply1.8 V, 3.3 V and 5 V rails; up to ~3.5 W
Applications10GbE, OC-192/STM-64, 10GFC, DWDM/tunable XFP
StatusLegacy — still common in transport and older routers

Specifications

  • INF-807710 Gigabit Small Form Factor Pluggable Module, Rev 4.5: mechanical, electrical (XFI) and the XFP management interface.
  • Contemporaries of the same era: INF-8476 (X2) and INF-8474 (XENPAK).

Management interface

XFP defines its own memory map in INF-8077i, at address A0h with a lower memory area and selectable upper tables (Table 01h holds serial ID, thresholds live in lower memory, and so on). It is not SFF-8472 and not SFF-8636 — an XFP must be decoded with the INF-8077i map or every field is misread.

XFP includes digital diagnostics (temperature, bias, Tx/Rx power, supply voltages) and, on DWDM variants, wavelength tuning registers.

Compatibility notes

  • Not mechanically or electrically compatible with SFP+.
  • Because the CDR is inside the module, XFP hosts are simpler; the trade-off is module power and size, which is why SFP+ won for dense switching.