Units & conversions
Optical work mixes logarithmic power, wavelengths, frequencies, bit rates and baud rates. This page collects the conversions you need at the bench, with the mental shortcuts engineers actually use.
dB and dBm
- dB is a ratio: 10 · log10(P₁/P₂). It describes gain or loss.
- dBm is an absolute power referenced to 1 mW: P(dBm) = 10 · log10(P/1 mW).
- Adding a loss in dB to a level in dBm gives a level in dBm: −3 dBm − 7 dB = −10 dBm. Never add two dBm values.
| dB | Power ratio | Rule of thumb |
|---|---|---|
| 0 | ×1 | — |
| 1 | ×1.26 | about a quarter more |
| 3 | ×2 | double / half |
| 6 | ×4 | — |
| 10 | ×10 | one decade |
| 20 | ×100 | — |
| 30 | ×1000 | — |
| dBm | mW | µW | Typical meaning |
|---|---|---|---|
| +10 | 10 | 10 000 | booster output, DWDM launch |
| +3 | 2 | 2 000 | strong LR/ER transmitter |
| 0 | 1 | 1 000 | typical single-mode Tx |
| −3 | 0.5 | 500 | typical short-reach Tx |
| −10 | 0.1 | 100 | healthy Rx on a short link |
| −18 | 0.016 | 16 | PIN receiver sensitivity (10G) |
| −24 | 0.004 | 4 | APD receiver sensitivity |
| −30 | 0.001 | 1 | very weak — check the link |
| −40 | 0.0001 | 0.1 | DDM resolution floor: "no light" |
Raw DDM power is stored in 0.1 µW steps: raw = µW × 10 (0 dBm → 10 000). Details in DDM parameters & units.
Link budget arithmetic
Budget = Tx power (min) − Rx sensitivity [dB]
Losses = fibre (km × dB/km) + connectors + splices + mux/demux + margin
Margin left = Budget − Losses (should stay ≥ 0, ideally ≥ 3 dB)
Worked example and component losses: CWDM mux/demux & link budget.
| Item | Typical loss |
|---|---|
| Single-mode fibre, 1310 nm | 0.33–0.35 dB/km |
| Single-mode fibre, 1550 nm | 0.18–0.22 dB/km |
| Multi-mode fibre, 850 nm | 2.5–3.5 dB/km |
| Connector pair (clean) | 0.1–0.3 dB |
| Fusion splice | 0.05–0.1 dB |
| Mechanical splice | 0.2–0.5 dB |
| 1:2 splitter | ~3.5 dB; each further doubling +3–3.5 dB |
| CWDM mux (8 ch) | 1.0–2.5 dB |
| DWDM AWG mux (40 ch) | 4–7 dB |
Wavelength ↔ frequency
λ · f = c, with c ≈ 299 792 458 m/s. Convenient forms:
λ (nm) = 299 792.458 / f (THz)
f (THz) = 299 792.458 / λ (nm)
| Wavelength | Frequency | Note |
|---|---|---|
| 850 nm | 352.7 THz | multi-mode VCSEL |
| 1310 nm | 228.8 THz | O-band |
| 1490 nm | 201.2 THz | GPON downstream |
| 1528.77 nm | 196.1 THz | C-band top (C61) |
| 1550 nm | 193.4 THz | C-band centre |
| 1552.52 nm | 193.1 THz | ITU anchor (C31) |
| 1563.86 nm | 191.7 THz | C-band bottom (C17) |
In the C-band 100 GHz ≈ 0.8 nm and 50 GHz ≈ 0.4 nm. Channel numbering and the full grid: DWDM and the ITU grid, Wavelength bands & channel plans.
Bit rate, baud and line coding
The number on the label (10G, 25G, 100G) is the payload rate. On the fibre the signal runs faster because of line coding and FEC, and PAM4 carries two bits per symbol.
| Nominal | Line coding / FEC | Signalling rate | Modulation | Symbol rate |
|---|---|---|---|---|
| 1 GbE | 8b/10b | 1.25 Gb/s | NRZ | 1.25 GBd |
| 10 GbE | 64b/66b | 10.3125 Gb/s | NRZ | 10.3125 GBd |
| 8GFC | 8b/10b | 8.5 Gb/s | NRZ | 8.5 GBd |
| 16GFC | 64b/66b | 14.025 Gb/s | NRZ | 14.025 GBd |
| 25 GbE (per lane) | 64b/66b + RS-FEC | 25.78125 Gb/s | NRZ | 25.78 GBd |
| 32GFC | 64b/66b + FEC | 28.05 Gb/s | NRZ | 28.05 GBd |
| 50G lane | RS(544,514) | 53.125 Gb/s | PAM4 | 26.5625 GBd |
| 100G lane | RS(544,514) | 106.25 Gb/s | PAM4 | 53.125 GBd |
| 200G lane | RS(544,514) | 212.5 Gb/s | PAM4 | 106.25 GBd |
Rules: 64b/66b adds 3.125 % (×66/64); RS(544,514) adds another ~5.8 % (×544/514); PAM4 halves the symbol rate for a given bit rate. This is why a "100G" lane runs at 53.125 GBd and why DDM nominal signalling rate bytes read 103 (×100 Mb/s) for 10GbE, not 100. Background: FEC & link training.
Bit-error ratio
| BER | Meaning | Time between errors at 10 Gb/s |
|---|---|---|
| 10⁻⁹ | poor | 0.1 s |
| 10⁻¹² | classic error-free target (NRZ optics) | ~100 s |
| 10⁻¹⁵ | post-FEC target for 25G+ | ~28 h |
| 2.4×10⁻⁴ | typical pre-FEC threshold for RS(544,514) | — corrected to <10⁻¹⁵ |
DDM raw units
| Monitor | Raw unit | Convert |
|---|---|---|
| Temperature | 1/256 °C, signed | °C = raw / 256 |
| Vcc | 100 µV | V = raw × 0.0001 |
| Tx bias | 2 µA | mA = raw × 0.002 |
| Tx / Rx power | 0.1 µW | mW = raw × 0.0001; dBm = 10·log10(mW) |
Distances and fibre units
- Module length fields: SMF in km (byte 14) and 100 m (byte 15); multi-mode in 10 m units (bytes 16–19) or metres for copper — see Memory map quick reference.
- 1 dB of extra loss ≈ 3 km of 1310 nm single-mode, ≈ 5 km of 1550 nm, ≈ 300 m of 850 nm multi-mode.
In CodingBox
CodingBox performs all DDM conversions and shows values in engineering units on the DDM screen, with the raw bytes available in the EEPROM editor when you need to check a conversion by hand.
Applying these conversions to a live link — expected loss, margin, both directions: Rx power & link budget; expected windows to compare with: Typical values.
Standard reaches per PMD and fibre grade to plug into the budget: Reach tables; how datasheets state Tx power, sensitivity and BER — and how to normalise them: Reading a datasheet.
The full design method behind this arithmetic — allowances by standard, penalties, margin policy, worked examples, attenuators: Link budget engineering.
The rest of the fibre arithmetic with worked examples — guidance parameters, dispersion, budgets, reflections, OTDR distance, latency, bend strain: Formulas & calculations.