Optical PMD reference by rate
Every optical Ethernet interface is a PMD (Physical Medium Dependent) defined in IEEE 802.3 or an industry MSA. The tables below list the ones you meet in practice, with fibre type, wavelength, nominal reach and connector — the facts a module's memory must agree with.
1 Gigabit
| PMD | Fibre | λ | Reach | Connector |
|---|
| 1000BASE-SX | MMF | 850 nm | 550 m (OM2) | LC |
| 1000BASE-LX | SMF (MMF with MCP) | 1310 nm | 10 km | LC |
| 1000BASE-EX | SMF | 1310 nm | 40 km | LC |
| 1000BASE-ZX (MSA) | SMF | 1550 nm | 80 km | LC |
| 1000BASE-BX-U/D | SMF, single fibre | 1310 / 1490 nm | 10–20 km | LC simplex |
10 Gigabit
| PMD | Fibre | λ | Reach | Connector |
|---|
| 10GBASE-SR | MMF | 850 nm | 300 m OM3 / 400 m OM4 | LC |
| 10GBASE-LRM | MMF | 1310 nm | 220 m (legacy OM1/OM2) | LC |
| 10GBASE-LR | SMF | 1310 nm | 10 km | LC |
| 10GBASE-ER | SMF | 1550 nm | 40 km | LC |
| 10GBASE-ZR (MSA) | SMF | 1550 nm | 80 km | LC |
| 10GBASE-BX | SMF, single fibre | 1270 / 1330 nm | 10–40 km | LC simplex |
25 Gigabit
| PMD | Fibre | λ | Reach | FEC |
|---|
| 25GBASE-SR | MMF | 850 nm | 70 m OM3 / 100 m OM4 | RS-FEC |
| 25GBASE-LR | SMF | 1310 nm | 10 km | RS-FEC |
| 25GBASE-ER | SMF | 1310 nm | 40 km | RS-FEC |
40 Gigabit (4 lanes)
| PMD | Fibre | λ | Reach | Connector |
|---|
| 40GBASE-SR4 | MMF ×8 | 850 nm | 100 m OM3 / 150 m OM4 | MPO-12 |
| 40GBASE-LR4 | SMF | 4 × CWDM (1271–1331) | 10 km | LC |
| 40GBASE-ER4 | SMF | 4 × CWDM | 40 km | LC |
| 40G PSM4 (MSA) | SMF ×8 | 1310 nm | 10 km | MPO-12 |
| 40G BiDi (vendor) | MMF | 2 × 850/900 nm | 100–150 m | LC |
100 Gigabit
| PMD | Lanes | Fibre | λ | Reach | Connector |
|---|
| 100GBASE-SR4 | 4×25G | MMF ×8 | 850 nm | 70 m OM3 / 100 m OM4 | MPO-12 |
| 100GBASE-SR10 | 10×10G | MMF ×20 | 850 nm | 100–150 m | MPO-24 |
| 100G CWDM4 (MSA) | 4×25G | SMF | 4 × CWDM | 2 km | LC |
| 100G PSM4 (MSA) | 4×25G | SMF ×8 | 1310 nm | 500 m | MPO-12 |
| 100GBASE-LR4 | 4×25G | SMF | 4 × LAN-WDM (1295–1310) | 10 km | LC |
| 100GBASE-ER4 | 4×25G | SMF | 4 × LAN-WDM | 40 km | LC |
| 100GBASE-DR | 1×100G PAM4 | SMF | 1310 nm | 500 m | LC |
| 100GBASE-FR / LR | 1×100G PAM4 | SMF | 1310 nm | 2 km / 10 km | LC |
200 and 400 Gigabit
| PMD | Lanes | Fibre | Reach | Connector |
|---|
| 200GBASE-SR4 / DR4 / FR4 / LR4 | 4×50G | MMF / SMF | 100 m / 500 m / 2 km / 10 km | MPO-12 / LC |
| 400GBASE-SR8 | 8×50G | MMF ×16 | 100 m | MPO-16 |
| 400GBASE-SR4.2 (BiDi) | 4×2×50G | MMF ×8 | 100 m | MPO-12 |
| 400GBASE-DR4 | 4×100G | SMF ×8 | 500 m | MPO-12 APC |
| 400GBASE-FR4 / LR4 | 4×100G | SMF, 4 × CWDM | 2 km / 10 km | LC |
| 400GBASE-FR8 / LR8 | 8×50G | SMF, 8 × LAN-WDM | 2 km / 10 km | LC |
| 400ZR (OIF) | coherent | SMF | ~120 km | LC |
800 Gigabit
| PMD | Lanes | Fibre | Reach | Connector |
|---|
| 800G-SR8 | 8×100G | MMF ×16 | 50–100 m | MPO-16 |
| 800G-DR8 | 8×100G | SMF ×16 | 500 m | MPO-16 APC |
| 800G 2×FR4 | 2×(4×100G) | SMF | 2 km | dual LC |
Reading it against module memory
A module states its PMD through the compliance codes and wavelength bytes in its identity block (SFF-8472 for SFP-class, SFF-8636/CMIS for QSFP-class), using values from SFF-8024. The Check transceiver screen decodes these so you can confirm a module is the PMD its label claims — and when recoding, keep the codes consistent with the real optics (an SR module coded as LR will not reach 10 km).
How these PMDs are built from electrical lanes, and the IEEE amendments that introduced each generation: Ethernet generations & lane rates.
Reach per fibre grade (OM1–OM5, OS2) for each PMD, plus Fibre Channel, InfiniBand, PON and cable lengths: Reach tables; the IEEE clause behind each PMD: Standards map.