Every optical Ethernet interface is a PMD (Physical Medium Dependent) defined in IEEE 802.3 or an industry MSA. The tables below list the ones you meet in practice, with fibre type, wavelength, nominal reach and connector — the facts a module's memory must agree with.

1 Gigabit

PMDFibreλReachConnector
1000BASE-SXMMF850 nm550 m (OM2)LC
1000BASE-LXSMF (MMF with MCP)1310 nm10 kmLC
1000BASE-EXSMF1310 nm40 kmLC
1000BASE-ZX (MSA)SMF1550 nm80 kmLC
1000BASE-BX-U/DSMF, single fibre1310 / 1490 nm10–20 kmLC simplex

10 Gigabit

PMDFibreλReachConnector
10GBASE-SRMMF850 nm300 m OM3 / 400 m OM4LC
10GBASE-LRMMMF1310 nm220 m (legacy OM1/OM2)LC
10GBASE-LRSMF1310 nm10 kmLC
10GBASE-ERSMF1550 nm40 kmLC
10GBASE-ZR (MSA)SMF1550 nm80 kmLC
10GBASE-BXSMF, single fibre1270 / 1330 nm10–40 kmLC simplex

25 Gigabit

PMDFibreλReachFEC
25GBASE-SRMMF850 nm70 m OM3 / 100 m OM4RS-FEC
25GBASE-LRSMF1310 nm10 kmRS-FEC
25GBASE-ERSMF1310 nm40 kmRS-FEC

40 Gigabit (4 lanes)

PMDFibreλReachConnector
40GBASE-SR4MMF ×8850 nm100 m OM3 / 150 m OM4MPO-12
40GBASE-LR4SMF4 × CWDM (1271–1331)10 kmLC
40GBASE-ER4SMF4 × CWDM40 kmLC
40G PSM4 (MSA)SMF ×81310 nm10 kmMPO-12
40G BiDi (vendor)MMF2 × 850/900 nm100–150 mLC

100 Gigabit

PMDLanesFibreλReachConnector
100GBASE-SR44×25GMMF ×8850 nm70 m OM3 / 100 m OM4MPO-12
100GBASE-SR1010×10GMMF ×20850 nm100–150 mMPO-24
100G CWDM4 (MSA)4×25GSMF4 × CWDM2 kmLC
100G PSM4 (MSA)4×25GSMF ×81310 nm500 mMPO-12
100GBASE-LR44×25GSMF4 × LAN-WDM (1295–1310)10 kmLC
100GBASE-ER44×25GSMF4 × LAN-WDM40 kmLC
100GBASE-DR1×100G PAM4SMF1310 nm500 mLC
100GBASE-FR / LR1×100G PAM4SMF1310 nm2 km / 10 kmLC

200 and 400 Gigabit

PMDLanesFibreReachConnector
200GBASE-SR4 / DR4 / FR4 / LR44×50GMMF / SMF100 m / 500 m / 2 km / 10 kmMPO-12 / LC
400GBASE-SR88×50GMMF ×16100 mMPO-16
400GBASE-SR4.2 (BiDi)4×2×50GMMF ×8100 mMPO-12
400GBASE-DR44×100GSMF ×8500 mMPO-12 APC
400GBASE-FR4 / LR44×100GSMF, 4 × CWDM2 km / 10 kmLC
400GBASE-FR8 / LR88×50GSMF, 8 × LAN-WDM2 km / 10 kmLC
400ZR (OIF)coherentSMF~120 kmLC

800 Gigabit

PMDLanesFibreReachConnector
800G-SR88×100GMMF ×1650–100 mMPO-16
800G-DR88×100GSMF ×16500 mMPO-16 APC
800G 2×FR42×(4×100G)SMF2 kmdual LC

Reading it against module memory

A module states its PMD through the compliance codes and wavelength bytes in its identity block (SFF-8472 for SFP-class, SFF-8636/CMIS for QSFP-class), using values from SFF-8024. The Check transceiver screen decodes these so you can confirm a module is the PMD its label claims — and when recoding, keep the codes consistent with the real optics (an SR module coded as LR will not reach 10 km).

How these PMDs are built from electrical lanes, and the IEEE amendments that introduced each generation: Ethernet generations & lane rates.

Reach per fibre grade (OM1–OM5, OS2) for each PMD, plus Fibre Channel, InfiniBand, PON and cable lengths: Reach tables; the IEEE clause behind each PMD: Standards map.