面向儲存的無損以太網:DCB、PFC、ECN
Ethernet drops frames when it is congested; storage protocols built for Fibre Channel or RDMA assume nothing is ever dropped. Data Center Bridging (DCB) closes the gap with per-priority flow control and bandwidth allocation, and RoCE adds congestion signalling on top. The result is only as lossless as its worst link: a marginal optic that drops one frame in a million is a storage incident. This page explains the mechanisms and translates them into physical-layer requirements.
The DCB toolkit
| Standard | Name | What it does |
|---|---|---|
| IEEE 802.1Qbb | PFC — priority-based flow control | pause frames per traffic class (0–7): a congested receiver stops one class without stopping the port |
| IEEE 802.1Qaz | ETS — enhanced transmission selection | guaranteed bandwidth shares per class (e.g. 50 % storage, 50 % LAN) |
| IEEE 802.1Qaz | DCBX — DCB exchange | LLDP-based negotiation of PFC/ETS settings between switch and NIC |
| IEEE 802.1Qau | CN — congestion notification | rarely deployed |
| RFC 3168 + DCQCN | ECN marking + rate control | the switch marks packets when queues build; RoCE NICs slow the flow before PFC is needed |
How RoCE stays lossless
- Storage/RDMA traffic is tagged with a dedicated priority (often 3 or 4) via DSCP or 802.1p.
- PFC is enabled only for that priority on every port along the path, with buffer headroom sized for the link speed and cable length (in-flight bytes).
- ECN thresholds mark packets early; NICs run DCQCN to reduce their rate, so PFC fires only as a last resort.
- ETS guarantees the storage class its bandwidth under LAN load.
- DCBX keeps NIC and switch settings consistent; mismatches silently break losslessness.
FC and InfiniBand achieve the same with credits at every link by default; Ethernet needs it configured, verified and monitored (FC protocol basics, InfiniBand transport).
What can go wrong
| Problem | Effect | Detection |
|---|---|---|
| PFC not enabled on one hop / wrong priority | drops under load; RDMA retransmits; latency spikes | pause counters zero where they should not be; drops on the class |
| PFC storm | a stuck receiver pauses upstream indefinitely; congestion spreads fabric-wide | pause frames flooding; watchdog counters |
| PFC deadlock | cyclic buffer dependency in Clos fabrics; all traffic on the class stops | requires deadlock detection / watchdog to break |
| Headroom too small for long cables/optics | drops despite PFC | drops with pause counters active |
| ECN thresholds wrong | too early: throughput loss; too late: PFC floods | ECN mark counters, CNP counters on NICs |
| Physical errors on a link (CRC, FEC uncorrectable) | frames lost that no flow control can recover | port error counters, FEC counters — VDM & FEC metrics |
iSCSI without DCB
iSCSI runs over TCP and survives loss, but pays for it in latency and retransmission. Best practice regardless of DCB:
- dedicated VLANs/subnets per fabric, two fabrics, MPIO on hosts;
- jumbo frames (MTU 9000) end to end;
- no oversubscription between initiators and targets; 25G/100G uplinks sized for the array;
- FEC on for every 25G+ link; CRC counters at zero;
- optionally PFC on the iSCSI class to smooth micro-bursts (many arrays recommend it).
Physical-layer requirements
| Requirement | Why | Practice |
|---|---|---|
| FEC enabled and matched on every 25G+ link | RoCE cannot tolerate the raw BER of unprotected 25G/50G lanes | FEC & link training |
| CRC and uncorrectable FEC = 0 | each lost frame stalls a queue | alert on any increment |
| Rx power inside the window with margin | marginal optics produce bursts of errors under temperature | Rx power & link budget |
| Consistent speed/duplex/AN | DAC needs AN + link training both ends | Copper & DAC |
| Cable length within headroom assumptions | headroom is computed from in-flight bytes | prefer DAC in rack, SR/AOC in row, DR/LR between rooms |
| Identity accepted by NIC and switch | rejected optics fall back to no link or reduced speed | Vendor lock |
Monitoring checklist
- Per port: pause frames sent/received per priority, ECN marks, drops per class, CRC, FEC corrected/uncorrectable, link flaps.
- Per NIC: CNPs sent/received, retransmissions, out-of-sequence, timeouts.
- Per optic: Rx/Tx power and temperature trends (Monitoring).
- Correlate storage tail-latency spikes with the above — the physical layer is guilty more often than the array.
In CodingBox
A lossless fabric is built from ordinary optics that are simply held to a higher standard. Incoming inspection on the bench — identity, checksums, live DDM against typical values, baseline stored — is how marginal modules are kept out of a fabric where one bad link costs an application its latency SLA (Check transceiver, DDM).
Where PFC and ECN sit among the other forwarding mechanisms, and how physical-layer errors surface in them: Forwarding basics.