CodingBox ሰነዶች

የEEPROM ማህደረ ትውስታ ካርታ፦ አጭር ማጣቀሻ

The one-page byte map for the three memory layouts CodingBox works with most: SFF-8472 (SFP class), SFF-8636 (QSFP+/QSFP28) and CMIS (QSFP-DD, OSFP, QSFP112, SFP-DD). Use it to find a field fast in the EEPROM editor; the editor names every byte on hover, and the specification documents remain the authority for edge cases.

Positions follow the current public revisions (SFF-8472 rev 12.x, SFF-8636 rev 2.x, CMIS 5.x). Older modules may implement earlier revisions — check the compliance byte.

SFF-8472 — A0h (serial ID)

BytesFieldNotes
0Identifier03h = SFP/SFP+/SFP28 (SFF-8024)
1Extended identifier04h = MOD_DEF 4 (two-wire ID)
2Connector07h LC, 01h SC, 0Ch MPO, 21h copper, 23h no separable
3–10Transceiver compliance codesEthernet 10G (3), SONET (4–5), Ethernet 1G (6), FC (7–10)
11Encoding64b/66b, 8b/10b, NRZ…
12Nominal signalling rate×100 Mb/s (103 = 10.3 Gb/s)
13Rate identifierrate-select scheme (SFF-8079)
14Length SMFkm
15Length SMF×100 m
16Length 50 µm OM2×10 m
17Length 62.5 µm OM1×10 m
18Length OM4 or copperm
19Length OM3×10 m
20–35Vendor nameASCII, space-padded
36Extended compliance codeSFF-8024 Table 4-4
37–39Vendor OUIIEEE company ID
40–55Vendor part numberASCII
56–59Vendor revisionASCII
60–61Wavelength (nm) or cable compliance1310 = 051Eh
62Fibre Channel speed 2 / unallocated
63CC_BASEchecksum of bytes 0–62
64–65OptionsTX_DISABLE, TX_FAULT, RX_LOS, rate select…
66–67Signalling rate max / min% above / below nominal
68–83Vendor serial numberASCII
84–91Date codeYYMMDDLL
92Diagnostic monitoring typebit 6 DDM, bit 5 internal cal, bit 4 external cal, bit 3 average/OMA
93Enhanced optionsalarm/warning flags, soft TX_DISABLE, soft rate select
94SFF-8472 compliancerevision the module follows
95CC_EXTchecksum of bytes 64–94
96–127Vendor specific
128–255Reserved (SFF-8079)

SFF-8472 — A2h (diagnostics)

BytesFieldNotes
0–39Thresholdstemp, Vcc, bias, Tx pwr, Rx pwr — each HA, LA, HW, LW (details)
40–55Optional thresholdslaser temp, TEC current
56–91External calibration constantsRx power polynomial, slopes/offsets (details)
92–94Reserved
95CC_DMIchecksum of bytes 0–94
96–105Real-time monitorstemp, Vcc, Tx bias, Tx pwr, Rx pwr (units)
106–109Optional monitorslaser temp / TEC
110Status / controlTX_DISABLE state, RS0/RS1, TX_FAULT, RX_LOS, data ready
111Reserved
112–113Alarm flags
114–115Optional controlsTx input EQ / Rx output emphasis
116–117Warning flags
118–119Extended status / controlsoft RS, power level
120–126Vendor specificpassword area 0x7B–0x7E (123–126) on protected modules (write protection)
127Table / page selectselects optional upper tables
128–247User EEPROM (Table 00h)writable scratch area
248–255Vendor control

SFF-8636 — lower page 00h (QSFP+/QSFP28)

BytesField
0Identifier (0Dh QSFP+, 11h QSFP28)
1Revision compliance
2Status: data-not-ready, IntL, flat memory
3Tx LOS (7–4) / Rx LOS (3–0)
4Tx adaptive-EQ fault / Tx fault
5Tx LOL / Rx LOL (CDR)
6–7Temperature / Vcc alarm-warning flags
9–14Per-lane Rx power, Tx bias, Tx power flags
22–23Module temperature
26–27Module Vcc
34–41Rx power, lanes 1–4
42–49Tx bias, lanes 1–4
50–57Tx power, lanes 1–4
86Tx disable per lane
87 / 88Rx / Tx rate select
93Power control (low-power, override)
98CDR control (Tx 7–4, Rx 3–0)
100–106Interrupt masks
119–122Password change entry
123–126Password entry (0x7B)
127Page select

SFF-8636 — upper page 00h (identity)

BytesField
128Identifier
129Extended identifier: power class, CDR present (bits 3/2), CLEI
130Connector
131–138Specification compliance (Ethernet, SONET, SAS, GbE, FC)
139Encoding
140Nominal bit rate (×100 Mb/s; FFh → see 222)
141Extended rate select compliance
142Length SMF (km)
143Length OM3 (×2 m)
144 / 145Length OM2 / OM1 (m)
146Length copper or OM4 (m)
147Device technology (laser type, cooled, tunable…)
148–163Vendor name
164Extended module codes (InfiniBand)
165–167Vendor OUI
168–183Vendor part number
184–185Vendor revision
186–187Wavelength (÷20 nm) or copper attenuation
188–189Wavelength tolerance (÷200)
190Max case temperature
191CC_BASE (128–190)
192Extended specification compliance (SFF-8024 Table 4-4)
193–195Options
196–211Vendor serial number
212–219Date code
220Diagnostic monitoring type
221Enhanced options
222Nominal bit rate (×250 Mb/s)
223CC_EXT (192–222)
224–255Vendor specific

Upper page 03h holds thresholds; page 02h user EEPROM; page 01h application select (SFF-8636).

CMIS — lower page and key pages

LocationField
Lower 0Identifier (18h QSFP-DD, 19h OSFP, 1Eh QSFP112, 1Ah SFP-DD)
Lower 1CMIS revision (e.g. 50h = 5.0)
Lower 2Module characteristics: flat memory, memory model
Lower 3Module state (bits 3–1: 1 LowPwr, 2 PwrUp, 3 Ready, 4 PwrDn, 5 Fault)
Lower 8–13Module flags
Lower 14–25Module monitors (temp 14–15, Vcc 16–17, aux)
Lower 26Module global controls (low-power, software reset)
Lower 118–121Password change
Lower 122–125Password entry
Lower 126Bank select
Lower 127Page select
Page 00h 128–255Identity: vendor 129–144, OUI 145–147, PN 148–163, rev 164–165, SN 166–181, date 182–189, CLEI 190–199, power class 200–201, connector 203, media type 212…
Page 01hAdvertisements: monitors implemented, CDR support, VDM, applications (86–117)
Page 02hThresholds
Page 10hLane controls: data-path, Tx disable, CDR enable (160/161), application select
Page 11hLane status and monitors: flags 134–153, Tx power 154–169, Tx bias 170–185, Rx power 186–201
Pages 20h–2FhVDM (Per-lane diagnostics)
Pages 9Fh, A0h+CDB command / reply

Full description: CMIS, MIS for SFP-DD.

Checksums

ChecksumCoversWhere
CC_BASE (SFP)A0h 0–62A0h 63
CC_EXT (SFP)A0h 64–94A0h 95
CC_DMI (SFP)A2h 0–94A2h 95
CC_BASE (QSFP)128–190191
CC_EXT (QSFP)192–222223
CMIS page checksumsper pagelast byte of the page

All are simple 8-bit sums. CodingBox recalculates them automatically on every write — a hand-edited dump with a stale checksum is rejected by most hosts (EEPROM recoding).

Protocol-level view of how these bytes are reached — addresses, paging, banks, timing: Two-wire interface. Which bytes each checksum covers and how to compute them: Checksums.

This page is the condensed view. Full byte-by-byte and bit-by-bit tables: SFF-8472 A0h · SFF-8472 A2h · SFF-8636 lower · SFF-8636 upper · CMIS lower · CMIS upper · CMIS lanes · XFP.

Power-class bytes across all families with the class ladders and real consumption figures: Power & consumption; which document defines each byte range and where to obtain it: Standards map.