Checksums: CC_BASE, CC_EXT, CC_DMI, CMIS pages · Specifications & standards · Optical transceivers & cables · Documentation · CodingBox
CodingBox Documentation

Checksums: CC_BASE, CC_EXT, CC_DMI, CMIS pages

Every management specification protects its identity block with one or more checksums — a single byte that lets the host detect a corrupted or half-written EEPROM before it trusts the contents. They are trivial to compute and easy to forget: a stale checksum after editing is the most common reason a freshly coded module is reported as invalid.

The algorithm

All of them use the same rule: add the bytes of the covered range as unsigned 8-bit values and keep the low 8 bits of the sum (sum modulo 256). No CRC, no polynomial.

sum = 0
for each byte b in range:
    sum = (sum + b) & 0xFF
checksum = sum

Example — the first five bytes of a 10GBASE-SR SFP: 03 04 07 10 00 → 3 + 4 + 7 + 16 + 0 = 30 = 1Eh. Continue through byte 62 and the result is CC_BASE.

Where each checksum lives

SpecificationChecksumLocationCovers
SFF-8472 (SFP)CC_BASEA0h byte 63A0h bytes 0–62
SFF-8472CC_EXTA0h byte 95A0h bytes 64–94
SFF-8472CC_DMIA2h byte 95A2h bytes 0–94 (thresholds and calibration constants)
SFF-8636 (QSFP)CC_BASEbyte 191upper page 00h bytes 128–190
SFF-8636CC_EXTbyte 223bytes 192–222
INF-8077i (XFP)CC_BASEbyte 191bytes 128–190
INF-8077iCC_EXTbyte 223bytes 192–222
CMISpage checksumpage 00h byte 222page 00h bytes 128–221
CMISpage checksumpage 01h byte 255page 01h bytes 130–254 (128–129 hold the inactive firmware version and are excluded)
CMISpage checksumpage 02h byte 255page 02h bytes 128–254
CMISpage checksumpage 04h byte 255page 04h bytes 128–254

Not covered by any checksum: the vendor-specific areas (SFP A0h 96–127, QSFP 224–255, CMIS 223–255), user EEPROM, the live monitors and flags, QSFP page 03h thresholds, and CMIS lane pages. Vendors may add their own integrity fields in vendor space — those are not part of the specification.

What hosts do with them

BehaviourResult of a bad checksum
Validate CC_BASE (most switches and routers)module shown as invalid, unsupported or EEPROM checksum error; port may errdisable; laser often kept off
Validate CC_EXT as wellsame, or only a log entry, depending on platform
Validate CC_DMIDDM shown as not supported or values ignored; the link itself is unaffected
Ignore checksums (many NICs, some open switches)module works; the error surfaces only in tools

A checksum failure is reported together with identity, so a module that also has a policy problem shows one message hiding the other — check the checksums first, they are the cheap fix. Symptom map: Symptom index.

When you must recompute

  • After editing anything in the covered ranges — vendor name, part number, serial, date code, compliance codes, wavelength, lengths, options, power class.
  • After applying thresholds or calibration constants on SFP (CC_DMI).
  • After restoring a partial image from another module.
  • Not needed for changes in vendor space, user EEPROM or A2h control bytes.

Order of operations: edit → recompute every affected checksum → write → read back → verify. Writing the checksum byte before the data it covers leaves a window where a power loss produces an invalid module.

Checksums and vendor locks

Correct checksums are necessary, not sufficient. A strict platform also checks the vendor block and, on locked designs, a proprietary signature in vendor space that the specification checksums know nothing about. Passing CC_BASE with a rejected identity looks like a vendor lock case, not a checksum case — Vendor lock, Vendor fields.

In CodingBox

CodingBox recalculates CC_BASE, CC_EXT, CC_DMI and the CMIS page checksums automatically on every write and highlights a mismatch when reading a module — a red checksum field on Check transceiver or in the EEPROM editor means the module was edited elsewhere without fixing it, or the EEPROM is corrupted.

Where each checksum sits among its neighbours: SFF-8472 A0h (63, 95), A2h (95), SFF-8636 upper (191, 223), CMIS upper pages (222, 255), XFP (191, 223).


If you find an inaccuracy or error in this material, select the relevant fragment and press Ctrl+Enter to .