SFF-8636 upper pages register map (00h, 03h) · Specifications & standards · Optical transceivers & cables · Documentation · CodingBox
CodingBox Documentation

SFF-8636 upper pages register map (00h, 03h)

Upper memory (bytes 128–255) of a QSFP+/QSFP28 module is paged through lower byte 127. Page 00h carries the identity block that hosts validate; page 03h carries the alarm/warning thresholds and per-lane signal-integrity controls; pages 01h and 02h hold the application-select table and user EEPROM. This page lists them byte by byte and bit by bit, compiled against SFF-8636 Rev 2.11 (rev 2.10 marks later additions). Narrative: SFF-8636; runtime bytes are in the Lower page 00h map.

Legend: rsvd = reserved · vendor = vendor specific · bit 7 = MSB.

Upper page 00h — identity, bytes 128–191 (covered by CC_BASE)

ByteFieldContents
128Identifieras lower byte 0 (0Dh QSFP+, 11h QSFP28)
129Extended identifier7–6 power class 1–4: 00 class 1 ≤ 1.5 W · 01 class 2 ≤ 2.0 W · 10 class 3 ≤ 2.5 W · 11 class 4 ≤ 3.5 W · 5 power class 8 implemented rev 2.10 (max power in lower byte 107) · 4 CLEI code present (page 02h) · 3 CDR present in Tx · 2 CDR present in Rx · 1–0 power class 5–7: 00 not used (see 7–6) · 01 class 5 ≤ 4.0 W · 10 class 6 ≤ 4.5 W · 11 class 7 ≤ 5.0 W
130ConnectorSFF-8024 Table 4-3: 07h LC · 0Ch MPO 1×12 · 0Dh MPO 2×16 · 23h no separable connector · 27h MPO 2×12 · 28h MPO 1×16
131Ethernet compliance7 extended — use byte 192 · 6 10GBASE-LRM · 5 10GBASE-LR · 4 10GBASE-SR · 3 40GBASE-CR4 · 2 40GBASE-SR4 · 1 40GBASE-LR4 · 0 40G active cable (XLPPI)
132SONET compliance7–4 rsvd · 3 40G OTN (OTU3B/OTU3C) · 2 OC-48 long reach · 1 OC-48 intermediate · 0 OC-48 short reach
133SAS/SATA compliance7 SAS 24 Gb/s rev 2.10 · 6 SAS 12 Gb/s · 5 SAS 6 Gb/s · 4 SAS 3 Gb/s · 3–0 rsvd
134Gigabit Ethernet compliance7–4 rsvd · 3 1000BASE-T · 2 1000BASE-CX · 1 1000BASE-LX · 0 1000BASE-SX
135FC link length / technology7 very long (V) · 6 short (S) · 5 intermediate (I) · 4 long (L) · 3 medium (M) · 2 rsvd · 1 longwave laser (LC) · 0 electrical inter-enclosure (EL)
136FC transmitter technology7 electrical intra-enclosure · 6 shortwave laser w/o OFC (SN) · 5 shortwave laser with OFC (SL) · 4 longwave laser (LL) · 3–0 rsvd
137FC transmission media7 twin axial (TW) · 6 shielded twisted pair (TP) · 5 miniature coax (MI) · 4 video coax (TV) · 3 multimode 62.5 µm (M6) · 2 multimode 50 µm (M5) · 1 OM3 · 0 single mode (SM)
138FC speed7 1200 MB/s · 6 800 · 5 1600 · 4 400 · 3 3200 · 2 200 · 1 extended (SFF-8024) · 0 100 MB/s
139EncodingSFF-8024 Table 4-2 (QSFP column): 00h unspecified · 01h 8B/10B · 02h 4B/5B · 03h NRZ · 04h SONET scrambled · 05h 64B/66B · 06h Manchester · 07h 256B/257B · 08h PAM4
140Nominal signalling rateper lane, units of 100 Mb/s (67h = 10.3 Gb/s); FFh → see byte 222
141Extended rate select compliance7–2 rsvd · 1–0 01 = rate select version 1 (bytes 87–88 valid); 00 = not implemented
142Length SMFkm (00h = not SMF)
143Length OM3units of 2 m
144Length OM2units of 1 m
145Length OM1units of 1 m
146Length copper / OM4copper or active cable: metres; OM4: units of 2 m (interpretation per byte 147 technology)
147Device technology7–4 transmitter technology: 0h 850 nm VCSEL · 1h 1310 nm VCSEL · 2h 1550 nm VCSEL · 3h 1310 nm FP · 4h 1310 nm DFB · 5h 1550 nm DFB · 6h 1310 nm EML · 7h 1550 nm EML · 8h other/undefined · 9h 1490 nm DFB · Ah copper unequalised · Bh copper passive equalised · Ch copper near & far end limiting active · Dh copper far end limiting · Eh copper near end limiting · Fh copper linear active equalisers · 3 wavelength control (1 = active) · 2 cooled transmitter · 1 detector type (1 = APD, 0 = PIN) · 0 tunable transmitter
148–163Vendor name16 ASCII
164Extended moduleInfiniBand: 7–5 rsvd · 4 EDR · 3 FDR · 2 QDR · 1 DDR · 0 SDR
165–167Vendor OUI—
168–183Vendor PN16 ASCII
184–185Vendor rev2 ASCII
186–187Wavelength / copper attenuationoptical: wavelength in 0.05 nm units (0x6598 = 1299.2 nm) · copper: 186 attenuation at 2.5 GHz (dB), 187 at 5.0 GHz
188–189Wavelength tolerance / attenuationoptical: ±tolerance in 0.005 nm units · copper: 188 at 7.0 GHz, 189 at 12.9 GHz
190Max case temperature°C (00h = 70 °C standard)
191CC_BASE(Σ bytes 128–190) mod 256

Upper page 00h — extended identity, bytes 192–255

ByteFieldContents
192Extended specification complianceSFF-8024 Table 4-4 (02h 100GBASE-SR4 · 03h LR4 · 06h CWDM4 · 07h PSM4 · 0Bh 100GBASE-CR4 · 11h 4×10GBASE-SR · 25h 100GBASE-DR · 40h–49h 50G/200G/400G codes …) — SFF-8024
193Options7 rsvd · 6 LPMode/TxDis pin function configurable rev 2.10 · 5 IntL/LOSL pin function configurable rev 2.10 · 4 Tx input EQ auto-adaptive capable · 3 Tx input EQ fixed programmable · 2 Rx output emphasis fixed programmable · 1 Rx output amplitude fixed programmable · 0 rsvd
194Options7 Tx CDR on/off control implemented · 6 Rx CDR on/off control implemented · 5 Tx CDR LOL flag implemented · 4 Rx CDR LOL flag implemented · 3 Rx squelch disable implemented · 2 Rx output disable capable · 1 Tx squelch disable implemented · 0 Tx squelch implemented
195Options7 page 02h provided · 6 page 01h provided · 5 rate select implemented · 4 Tx_Disable implemented · 3 Tx_Fault implemented · 2 Tx squelch reduces OMA (1) or Pave (0) · 1 Tx LOS implemented · 0 pages 20h–21h implemented
196–211Vendor SN16 ASCII
212–219Date codeYYMMDD + 2 lot
220Diagnostic monitoring type7–4 rsvd · 3 Rx power measurement: 1 = average, 0 = OMA · 2 Tx power monitor implemented · 1–0 rsvd
221Enhanced options4 initialisation-complete flag implemented (lower byte 6 bit 0) · 3 rate selection declaration (0 = via byte 141 / rate select v1, 1 = via application select page 01h) · 2–0 later-revision features (TC readiness flag, software reset, Tx-disable fast mode) — check the revision
222Extended signalling rateper lane, units of 250 Mb/s, valid when byte 140 = FFh (67h = 25.75 Gb/s; D5h = 53.125 GBd)
223CC_EXT(Σ bytes 192–222) mod 256
224–255Vendor specificnot checksummed; signatures and production data

Page 01h — application select table

Populated only when byte 195 bit 6 is set; defines applications selectable through lower bytes 89–92 / 94–97 (SFF-8079 model). Rarely implemented on QSFP28; CMIS replaced it with application descriptors.

Page 02h — user EEPROM

BytesContents
128–137CLEI code (10 ASCII) when byte 129 bit 4 is set
128–255otherwise free user EEPROM, not checksummed

Page 03h — thresholds, bytes 128–223

BytesFieldBytesField
128–129Temperature high alarm130–131Temperature low alarm
132–133Temperature high warning134–135Temperature low warning
136–143rsvd——
144–145Vcc high alarm146–147Vcc low alarm
148–149Vcc high warning150–151Vcc low warning
152–175rsvd / vendor——
176–177Rx power high alarm178–179Rx power low alarm
180–181Rx power high warning182–183Rx power low warning
184–185Tx bias high alarm186–187Tx bias low alarm
188–189Tx bias high warning190–191Tx bias low warning
192–193Tx power high alarm194–195Tx power low alarm
196–197Tx power high warning198–199Tx power low warning
200–223rsvd——

Channel thresholds apply to all four lanes; formats as the monitors (temperature 1/256 °C, Vcc 100 µV, bias 2 µA, power 0.1 µW) — Thresholds & alarms.

Page 03h — channel controls and masks, bytes 224–255

ByteFieldBits
224–225vendor—
226–233rsvd / vendor—
234Tx input equalisation7–4 Tx1 EQ level · 3–0 Tx2 EQ level (0–15, dB steps per vendor)
235Tx input equalisation7–4 Tx3 · 3–0 Tx4
236Rx output emphasis7–4 Rx1 · 3–0 Rx2
237Rx output emphasis7–4 Rx3 · 3–0 Rx4
238Rx output amplitude7–4 Rx1 · 3–0 Rx2 (codes 0–3: 100–400 / 300–600 / 400–800 / 600–1200 mVpp)
239Rx output amplitude7–4 Rx3 · 3–0 Rx4
240Squelch disable7–4 Rx4…Rx1 squelch disable · 3–0 Tx4…Tx1 squelch disable
241Rx output disable7–4 rsvd · 3–0 Rx4…Rx1 output disable
242Rx power masks lanes 1–2layout as lower byte 9
243Rx power masks lanes 3–4as lower byte 10
244Tx bias masks lanes 1–2as lower byte 11
245Tx bias masks lanes 3–4as lower byte 12
246Tx power masks lanes 1–2as lower byte 13
247Tx power masks lanes 3–4as lower byte 14
248–253rsvd—
254–255vendor—

Pages 20h–21h

Optional (byte 195 bit 0); rev 2.10 reserves them for extended per-lane functions and vendor use — consult the module's datasheet.

Reading a 100GBASE-SR4 identity

A typical SR4 reads: byte 128 = 11h; 129 = 00h (class 1) or 40h (class 2); 130 = 0Ch (MPO); 131 = 80h (extended); 139 = 05h (64B/66B); 140 = FFh; 222 = 67h (25.75 Gb/s per lane); 143 = 23h (70 m OM3 in 2 m units = 35); 146 = 32h (100 m OM4 / 2 = 50); 147 = 00h (850 nm VCSEL, PIN); 186–187 = 850 nm / 0.05 = 17 000 = 4268h (the exact value depends on the module's nominal wavelength field); 192 = 02h (100GBASE-SR4); 195 = 3Ch–BCh depending on the pages provided. Values differ between vendors; the point is which bytes to look at.


If you find an inaccuracy or error in this material, select the relevant fragment and press Ctrl+Enter to .