Standards map: who publishes what · Reference · Optical transceivers & cables · Documentation · CodingBox
CodingBox Documentation

Standards map: who publishes what

A single 100G link touches a dozen documents from six organisations: the IEEE clause that defines the PMD, the SFF document for the module's memory, the OIF agreement for the electrical interface, the ITU-T recommendation for the fibre, the IEC standards for the connector and laser safety, an MSA for the form factor. This page maps the bodies, their document families and numbering, the IEEE 802.3 clauses by PMD, and the question each document answers — so "which spec says so?" has a quick answer.

The bodies

BodyScope for opticsDocument styleAccess
IEEE 802.3 (Ethernet Working Group)PMDs, PCS, FEC, AN, AUIs, EPONone standard (802.3-2022) built from amendments (802.3ba, bs, cd, cu, ck, db, df, dj…); content by clausefree PDFs 6 months after publication (IEEE GET program)
SNIA SFF TA TWG (ex SFF Committee)module mechanics, cages, connectors, management memory (SFF-8472, 8636, 8024)SFF-8xxx, SFF-TA-1xxxfree
OIF (Optical Internetworking Forum)electrical interfaces (CEI), coherent pluggables (400ZR, 800ZR), CMIS 5.x, C-CMIS, co-packagingImplementation Agreements (IA)free
ITU-T SG15fibre types, WDM grids, DWDM/CWDM interfaces, OTN, PON (G-PON, XG(S)-PON, 50G-PON)G.xxx recommendationsfree
IEC TC 86fibre, cables, connectors, test methods, laser safety, transceiver testIEC 6xxxxpaid
ISO/IEC JTC1 SC25 / TIA TR-42structured cabling, fibre grades OM/OSISO/IEC 11801, ANSI/TIA-568, TIA-492paid
INCITS T11Fibre Channel physical (FC-PI-x), framing, switchingFC-PI-6, FC-PI-7, FC-FSdrafts free, standards paid
IBTA (InfiniBand Trade Association)IB architecture, physical layer, cable memoryIBTA Vol 1 / Vol 2registration
MSA groupsform factors and optical interfaces outside IEEEQSFP-DD, OSFP, SFP-DD, COBO, CWDM4, PSM4, 100G Lambda, 4WDM, SWDM, 400G BiDi, OpenZR+, Open Eye, LPO, 800G Pluggable, OSFP-XDfree (MSA overview)
Ethernet Alliance / Ethernet Technology Consortium / UEC / UALinkinterop plugfests, roadmap; 25G/50G consortium specs; AI transport—free
FSAN / Broadband Forum / IEEE 1904PON roadmaps, PON management (SIEPON)TR-xxx, 1904.1mostly free
FDA CDRH / IEClaser safety regulation21 CFR 1040.10; IEC 60825-1/-2—
O-RAN Alliance / CPRIfronthaul interfaces and optics requirementsO-RAN WG4/WG9 specsfree

IEEE 802.3 clause map

ClauseDefinesAmendment
36 / 371000BASE-X PCS/PMA; 1G auto-negotiation802.3z (1998)
381000BASE-SX / LX PMD802.3z
401000BASE-T802.3ab
46 / 47XGMII; XAUI802.3ae
4910GBASE-R PCS (64b/66b)802.3ae
5210GBASE-SR / LR / ER PMD802.3ae
5510GBASE-T802.3an
58 / 59 / 60100BASE-LX10/BX10; 1000BASE-LX10/BX10; 1000BASE-PX (EPON)802.3ah
6810GBASE-LRM802.3aq
72 / 73 / 7410GBASE-KR; backplane/copper auto-negotiation; BASE-R FEC802.3ap
7510G-EPON PMDs802.3av
82 / 8340G/100G PCS; PMA802.3ba
84 / 8540GBASE-KR4; 40GBASE-CR4 / 100GBASE-CR10802.3ba
8640GBASE-SR4 / 100GBASE-SR10802.3ba
87 / 8840GBASE-LR4 (ER4: 802.3bm); 100GBASE-LR4 / ER4802.3ba
8940GBASE-FR802.3bg
91RS-FEC (528,514) for 100G802.3bj
92 / 93 / 94100GBASE-CR4; KR4; KP4 (RS 544,514)802.3bj
95100GBASE-SR4802.3bm
Annex 83D / 83ECAUI-4 chip-to-chip / chip-to-module802.3bm
107 / 108 / 10925GBASE-R PCS; RS-FEC; PMA802.3by
110 / 111 / 11225GBASE-CR / CR-S; KR; SR802.3by
11325GBASE-T / 40GBASE-T802.3bq
11425GBASE-LR / ER802.3cc
119 / 120200G/400G PCS; PMA802.3bs
121 / 122200GBASE-DR4; 200GBASE-FR4/LR4, 400GBASE-FR8/LR8 (ER4/ER8: 802.3cn)802.3bs
123 / 124400GBASE-SR16; 400GBASE-DR4802.3bs
Annex 120C / 120D / 120E200GAUI-8/400GAUI-16 C2C; C2M; 400GAUI-8 C2M802.3bs
1262.5G/5GBASE-T802.3bz
133 / 134 / 13550GBASE-R PCS; RS-FEC; PMA802.3cd
136 / 13750GBASE-KR/100GBASE-KR2/200GBASE-KR4; 50GBASE-CR/100GBASE-CR2/200GBASE-CR4802.3cd
13850GBASE-SR, 100GBASE-SR2, 200GBASE-SR4; 400GBASE-SR8 (802.3cm)802.3cd / cm
13950GBASE-FR / LR (ER: 802.3cn)802.3cd
140100GBASE-DR; 100GBASE-FR1 / LR1 (802.3cu)802.3cd / cu
141–14425G/50G-EPON802.3ca
150400GBASE-SR4.2 (BiDi)802.3cm
151400GBASE-FR4 / LR4-6802.3cu
154100GBASE-ZR802.3ct
156400GBASE-ZR802.3cw
162 / 163100G/lane backplane (KR1/KR2/KR4); copper (CR1/CR2/CR4)802.3ck
Annex 120F / 120G100GAUI-1, 200GAUI-2, 400GAUI-4 C2C / C2M802.3ck
167100GBASE-VR1/SR1, 200GBASE-VR2/SR2, 400GBASE-VR4/SR4 (100G/lane MMF)802.3db
800GBASE clauses800GBASE-R PCS, CR8/KR8, VR8/SR8, DR8/DR8-2802.3df (2024)
1.6TBASE / 200G-per-lane200G electrical lanes, 1.6TBASE-DR8, 800GBASE-DR4802.3dj (in progress)

Full PMD list with reaches: PMD reference, Reach tables.

SFF / SNIA documents most used

DocumentSubject
SFF-8472SFP family management interface (A0h/A2h, DDM)
SFF-8636QSFP family management interface
SFF-8024shared code tables (identifiers, connectors, encodings)
SFF-8079 / SFF-8089SFP rate select
SFF-8418 / SFF-8419SFP+ high-speed electrical; power and low-speed electrical
SFF-8431SFP+ (SFI) electrical and management
SFF-8432 / SFF-8433SFP+ mechanical; ganged cages
SFF-8661 / 8662 / 8663 / 8679QSFP28 module, connector, cage; QSFP+ 4-lane electrical/pinout
SFF-8665QSFP28 "solution" (power classes, rate)
SFF-8690tunable SFP+ memory map
SFF-8071 / 8081SFP+ 1x 10 Gb/s / 28 Gb/s (SFP28) pluggable solution
SFF-TA-1004tunable QSFP? (check catalog)
INF-8074i / INF-8077iSFP MSA (original); XFP MSA

Complete list with groups: MSA specification catalog.

ITU-T recommendations

RecommendationSubject
G.651.150/125 µm multi-mode fibre
G.652 (A–D)standard single-mode fibre; G.652.D = low water peak, the default
G.653 / G.654 / G.655 / G.656dispersion-shifted; cut-off shifted low-loss (submarine, long-haul); NZ-DSF; wideband NZ-DSF
G.657 (A1/A2/B3)bend-insensitive single-mode
G.694.1 / G.694.2DWDM frequency grid; CWDM wavelength grid (Wavelength bands)
G.695CWDM application interfaces
G.698.1 / G.698.2DWDM single-channel interfaces (black-link)
G.959.1OTN physical layer interfaces
G.709 / G.798OTN frame structure; OTN equipment
G.975 / G.975.1FEC for submarine/OTN
G.671passive optical components
G.984.x / G.987.x / G.9807.1 / G.989.x / G.9804.xGPON; XG-PON; XGS-PON; NG-PON2; 50G-PON (PON standards)
G.8262 / G.8275SyncE; PTP telecom profiles

IEC, ISO/IEC, TIA

StandardSubject
IEC 60793 / 60794optical fibres; optical cables
IEC 61754-4 / -7 / -20SC; MPO; LC connector interfaces
IEC 61755connector optical interfaces (grades)
IEC 61300-3-35endface inspection criteria (the pass/fail scratches and defects)
IEC 61280-4-1 / -4-2attenuation measurement MMF; SMF
IEC 60825-1 / 60825-2laser safety classes; fibre communication systems (Labels)
IEC 62150-xfibre optic active components test methods
ISO/IEC 11801generic cabling; OM1–OM5, OS1a/OS2 definitions
ANSI/TIA-568.3optical fibre cabling components
TIA-492AAAA…AAAEOM1, OM2, OM3, OM4, OM5 fibre specifications
TIA-604-x (FOCIS)connector intermateability (FOCIS-10 LC, FOCIS-5 MPO)
TIA-598fibre colour coding
ANSI/TIA-942data-centre infrastructure

Fibre Channel, InfiniBand, OIF

DocumentSubject
FC-PI-2 / -4 / -5 / -6 / -6P / -7 / -84 / 8 / 16 / 32 / 128 (parallel) / 64 / 128 (serial) GFC physical (FC speeds)
FC-FS-x / FC-SW-xframing and signalling; switch fabric
IBTA Vol 1InfiniBand architecture, transport
IBTA Vol 2physical layer: electrical, optical, cable EEPROM and identity (IB cables)
OIF CEI-28G / -56G / -112G / -224Gelectrical lane interfaces (VSR, MR, LR, XSR)
OIF 400ZR / 800ZR IAcoherent pluggable interoperability (Coherent)
OIF CMIS 5.x, C-CMISmanagement for QSFP-DD/OSFP; coherent extensions (CMIS)
OIF ELSFP, co-packaging IAsexternal laser sources, CPO

Which document answers which question

QuestionLook in
Reach, wavelength, Tx/Rx limits of a PMDIEEE 802.3 clause (Ethernet), FC-PI-x, IBTA Vol 2, MSA spec
What the EEPROM bytes meanSFF-8472 / SFF-8636 / CMIS / INF-8077i (Memory map)
Code tables (identifier, connector, encoding)SFF-8024
Module mechanics, cage, pinoutSFF-8432/8433, SFF-8661…8663, QSFP-DD/OSFP MSA hardware specs
Electrical interface to the hostSFF-8431 (SFI), IEEE AUI annexes, OIF CEI
Fibre attenuation and dispersionITU-T G.652/G.657; ISO/IEC 11801 for OM/OS grades
Connector loss, cleanliness pass/failIEC 61755, IEC 61300-3-35
Whether the module is eye-safeIEC 60825-1, label
WDM channel frequenciesITU-T G.694.1 / G.694.2
PON power budgets and wavelengthsITU-T G.984 / G.9807; IEEE 802.3 Cl. 60/75/141
FEC type requiredIEEE clause of the PMD (Cl. 74, 91, 108, 134)

In CodingBox

CodingBox implements the SFF-8472, SFF-8636, SFF-8024, CMIS and INF-8077i documents for reading and editing memory, and names the IEEE/FC/IB codes it decodes from the compliance bytes — the specifications section holds the byte-level detail (MSA & standards, Spec revisions).

The standards of the fibre and the plant — ITU-T G.65x, IEC 60793/60794/61300/61753, TIA-568/606, ISO/IEC 11801/14763, Telcordia GR-20/GR-326 and national documents: Standards of fibre-optic links.


If you find an inaccuracy or error in this material, select the relevant fragment and press Ctrl+Enter to .