交換機角色與拓撲:光模組各自裝在哪裏
The same 100G module is a cheap DAC in one rack, an SR4 across the room, a LR4 between buildings and a DWDM channel between cities. Which one a port gets is decided by the switch's role in the network and the topology around it. This page maps the classic campus tiers and the data-centre leaf–spine to the optics, distances and counts they imply — so a bill of materials can be read off the design.
Campus: access, distribution, core
| Tier | Role | Typical ports | Downlinks | Uplinks and optics |
|---|---|---|---|---|
| Access | connects end devices | 24–48 × RJ45 (1G/mGig, PoE) + 2–4 SFP+/SFP28 uplinks | copper | 10G/25G SR (in-building MMF), LR (between buildings), sometimes 1G LX |
| Distribution / aggregation | aggregates access switches per building or floor group | 24–48 × SFP+/SFP28, 4–8 × QSFP28 | 10G/25G SR/LR | 40G/100G SR4/LR4 to core; CWDM/DWDM if fibre is scarce |
| Core | interconnects distribution, routes | QSFP28/QSFP-DD | 100G/400G | LR4/FR4/ER4 between sites; CWDM or DWDM over leased fibre |
| Collapsed core | small sites: distribution + core in one | mixed | — | — |
Campus distances are metres to a few kilometres: SR on OM3/OM4 inside buildings, LR/LX on single-mode between them; the reach classes in PMD reference.
Data centre: leaf–spine (Clos)
| Role | Also called | Ports | Downlinks | Uplinks |
|---|---|---|---|---|
| Leaf | ToR (top of rack), access | 48 × SFP28/SFP56 + 8 × QSFP28/QSFP-DD, or 32 × QSFP-DD | servers: 25G/50G/100G — DAC in rack (≤ 3 m), AOC/SR to adjacent racks | to every spine: 100G/400G SR4/DR4/AOC (≤ 100 m) |
| Spine | aggregation, fabric | 32–64 × QSFP28/QSFP-DD/OSFP | leaves | to super-spine or border: DR4/FR4 (500 m–2 km) |
| Super-spine / core | pod interconnect | high-radix 400G/800G | spines | DR/FR within the campus; ZR/ZR+ for DCI (Coherent) |
| Border leaf | edge to WAN/internet | mixed | — | LR/ER/CWDM/DWDM to carriers |
| Management | out-of-band | 1G RJ45/SFP | BMCs, consoles | 1G/10G LR to the OOB core |
Rules of thumb: leaf–spine links are all the same speed and FEC; oversubscription (downlink capacity ÷ uplink capacity) of 3:1 is common for general compute, 1:1 for AI and storage (GPU fabrics).
Rail-optimised AI fabrics
GPU nodes connect each NIC to a different leaf, so most server links leave the rack — AOC and optics instead of DAC — and the cable count per GPU is one per tier (Cabling an AI cluster).
Storage and SAN
Fibre Channel switches form their own fabric (edge–core or core–edge–core) with 16/32/64GFC SW optics in a room and LW between rooms; Ethernet storage rides the leaf–spine with lossless classes (SAN design, Lossless Ethernet).
Distance → optic
| Segment | Distance | Medium | Optic |
|---|---|---|---|
| Server to ToR | ≤ 3 m | copper | DAC (Cable internals) |
| Server to end-of-row leaf | 3–30 m | AOC or MMF | AOC, SR |
| Leaf to spine, same hall | 10–100 m | OM4 or SMF | SR4/SR8, DR4/DR8 |
| Between halls / buildings | 100 m – 2 km | SMF | DR, FR4, LR/LX |
| Campus / metro | 2–40 km | SMF | LR, ER, CWDM, 4WDM |
| Regional DCI | 40–120 km | SMF, amplified | ZR/ZR+, DWDM transponders |
| Long haul | > 120 km | SMF, amplified | DWDM line systems (Network design & OTN) |
Fibre-scarce paths use CWDM or DWDM to multiply capacity per strand; single-fibre BiDi where only one strand exists.
Counting optics from a design
Example: one pod of 16 racks, 32 servers per rack, 2 × 25G per server, 4 spines.
| Item | Count |
|---|---|
| Server links (2 × 25G × 32 × 16) | 1 024 DAC |
| Leaf uplinks (16 leaves × 4 spines × 2 × 100G) | 128 links → 256 QSFP28 SR4/DR4 + 128 MPO trunks |
| Spine to super-spine (4 spines × 8 × 100G) | 32 links → 64 modules |
| Border + OOB | 8–16 LR modules, 48 1G |
| Spares (5 %) | ~20 |
Multiply by two for the second fabric if the design is dual-plane.
Roles and policy
Role also decides how strict the platform is about optics: carrier and SAN gear tends to enforce OEM branding; data-centre leaf–spine on merchant silicon is often permissive; campus access varies by vendor (How each NOS validates a module, Vendor lock).
In CodingBox
A role-based bill of materials is a list of PMDs and part numbers; CodingBox verifies each delivered module against it (type, reach, wavelength, PN) and codes identities where the design calls for OEM-compatible modules (Check transceiver, Code database).
Turning a design into a purchase and a working rack — selection criteria, optics bill of materials, commissioning checklist and acceptance test: Selecting & commissioning; the L2/L3 mechanics behind these topologies: Forwarding basics.
The cabling under these topologies — structured cabling hierarchy, data-centre patterns (EoR, MoR, ToR, trunks and cassettes), fibre-count planning: Fibre network topologies.