সংক্ষিপ্ত রূপ A–Z
Optics documentation is written in acronyms: a datasheet line reads "SFP28 SR, 850 nm VCSEL, RS-FEC, OMA −6 dBm, DDM per SFF-8472". This index expands the abbreviations you meet in datasheets, switch output and CodingBox screens, with one line of meaning and a link to the material that explains the concept. For definitions of concepts rather than expansions see the Glossary.
A–B
| Abbr. | Expansion | Meaning |
|---|
| A0h / A2h | two-wire addresses 0xA0 / 0xA2 | identity and diagnostics memory of SFP-class modules (Memory map) |
| AEC | Active Electrical Cable | copper cable with retimers/DSP in the plugs (Cable internals) |
| ACC | Active Copper Cable | copper cable with linear amplifiers, no retiming |
| AN | Auto-Negotiation | speed/FEC negotiation, IEEE 802.3 Clause 73 on DAC (FEC & AN) |
| AOC | Active Optical Cable | fibre cable with fixed transceivers at both ends |
| APC | Angled Physical Contact | 8° angled connector polish, green (Connectors) |
| APD | Avalanche Photodiode | high-sensitivity receiver for long reach (Receivers) |
| ASE | Amplified Spontaneous Emission | noise generated by optical amplifiers (OSNR) |
| ASIC | Application-Specific Integrated Circuit | the switch forwarding chip (Inside a switch) |
| AUI | Attachment Unit Interface | chip-to-module electrical interface: XAUI, CAUI-4, 400GAUI-8… |
| AWG | Arrayed Waveguide Grating / American Wire Gauge | DWDM mux technology / copper conductor gauge in DAC |
| BASE-R / BASE-X | — | IEEE PCS families: 64b/66b (R) and 8b/10b (X) |
| BER | Bit Error Ratio | errored bits ÷ transmitted bits (Units) |
| BiDi | Bidirectional | one-fibre link with two wavelengths (Wavelength bands) |
| BOSA | Bidirectional Optical Sub-Assembly | TOSA + ROSA + filter in one package |
C–D
| Abbr. | Expansion | Meaning |
|---|
| CAUI | 100 Gb/s AUI | CAUI-10 (10 × 10G), CAUI-4 (4 × 25G) |
| CC_BASE / CC_EXT / CC_DMI | checksums | EEPROM checksums per SFF-8472/8636 (Checksums) |
| CDB | Command Data Block | CMIS command mechanism (firmware upgrade etc.) (CMIS) |
| CDR | Clock and Data Recovery | retiming circuit (CDR) |
| CEI | Common Electrical I/O | OIF electrical interface specs (CEI-28G, -56G, -112G) |
| CFP | C Form-factor Pluggable | 100G/coherent module family |
| CMIS | Common Management Interface Specification | management for QSFP-DD, OSFP and others |
| COB | Chip-on-Board | die-on-PCB packaging (COB) |
| CPO | Co-Packaged Optics | optics integrated with the switch ASIC |
| CPRI / eCPRI | Common Public Radio Interface | mobile fronthaul protocols (Fronthaul) |
| CR / CR4 / CR8 | copper | IEEE PMD names for DAC (25GBASE-CR, 100GBASE-CR4) |
| CRC | Cyclic Redundancy Check | frame check; CRC errors = link errors |
| CWDM | Coarse WDM | 20 nm grid, 18 channels (CWDM) |
| DAC | Direct Attach Cable | passive twinax copper cable |
| DCM | Dispersion Compensation Module | fibre spool or grating compensating chromatic dispersion |
| DDM / DOM | Digital Diagnostics Monitoring / Digital Optical Monitoring | live temperature, voltage, bias, powers (DDM basics) |
| DFB | Distributed Feedback laser | single-mode laser for 1310/1550 nm (Lasers) |
| DML | Directly Modulated Laser | laser whose current is modulated |
| DP | Data Path | CMIS lane group with its state machine |
| DR / DR4 / DR8 | 500 m PMD | single-mode parallel 500 m PMDs |
| DSP | Digital Signal Processor | PAM4 and coherent signal processing (DSP) |
| DWDM | Dense WDM | 100/50 GHz grid (DWDM) |
E–G
| Abbr. | Expansion | Meaning |
|---|
| EDFA | Erbium-Doped Fibre Amplifier | C/L-band optical amplifier |
| EEPROM | Electrically Erasable Programmable ROM | module memory |
| EML | Externally Modulated Laser | DFB + electro-absorption modulator |
| EPON / GPON / XGS-PON | Ethernet / Gigabit / 10G-symmetric PON | PON generations (PON standards) |
| ER / ER4 / ER8 | Extended Reach | 40 km PMDs |
| ER (optical) | Extinction Ratio | P1/P0 of the transmitter, dB |
| ESD | Electrostatic Discharge | handling hazard for modules |
| FC / GFC | Fibre Channel / Gigabit FC | storage network (Fibre Channel) |
| FEC | Forward Error Correction | BASE-R (Fire code), RS-FEC (528/544) |
| FP | Fabry-Pérot laser | multi-mode laser for short SMF links |
| FR / FR4 / FR8 | 2 km PMD | single-mode 2 km PMDs |
| FTTx | Fibre To The x | home/building/curb access |
| GBIC | Gigabit Interface Converter | first-generation 1G module (GBIC) |
| GAUI | e.g. 400GAUI-8 | AUI at 400G with 8 lanes |
| GBd | gigabaud | symbols per second (Units) |
H–L
| Abbr. | Expansion | Meaning |
|---|
| HA / HW / LA / LW | High Alarm / High Warning / Low Alarm / Low Warning | DDM thresholds (Thresholds) |
| HBA | Host Bus Adapter | FC server adapter |
| HDR / NDR / XDR | InfiniBand generations | 200 / 400 / 800 Gb/s (InfiniBand speeds) |
| I²C / TWI | Inter-Integrated Circuit / Two-Wire Interface | the management bus (Two-wire interface) |
| IB | InfiniBand | HPC/AI interconnect |
| IEC | International Electrotechnical Commission | connector, fibre, laser-safety standards (Standards map) |
| IEEE 802.3 | Ethernet working group | PMD, PCS, FEC standards |
| INF-8077i | XFP MSA document | XFP management (XFP) |
| ITU-T | International Telecommunication Union, Telecom sector | fibre (G.652), grids (G.694.x), PON (G.984/G.9807), OTN (G.709) |
| KR / KR4 | backplane | IEEE backplane PMDs; KP4 = RS(544,514) FEC |
| LC | Lucent Connector | the standard duplex connector |
| LOL | Loss of Lock | CDR cannot lock |
| LOS | Loss of Signal | receiver sees no light |
| LPMode / LowPwr | Low Power mode | module held at ≤ 1.5 W (Power & thermal) |
| LPO | Linear Pluggable Optics | DSP-less module relying on host equalisation |
| LR / LR4 / LR8 | Long Reach | 10 km PMDs |
| LRM | Long Reach Multimode | 10GBASE-LRM, 220 m on OM1/OM2 |
| LWDM / LAN-WDM | LAN Wavelength Division Multiplexing | 800 GHz grid around 1300 nm used by LR4/ER4 |
| LW / SW / ELW | Long / Short / Extended Long Wave | Fibre Channel optic types |
M–O
| Abbr. | Expansion | Meaning |
|---|
| MAC | Media Access Control | Ethernet framing layer |
| MDIO | Management Data I/O | PHY management bus (not used by modules) |
| MIS | Management Interface Specification | SFP-DD management (MIS) |
| MMF / SMF | Multi-Mode / Single-Mode Fibre | 50/62.5 µm core vs 9 µm |
| ModPrsL / MOD_ABS | Module Present (active low) / Module Absent | presence pin |
| MPO / MTP | Multi-fibre Push-On / MTP® brand | 12/16/24-fibre connector |
| MSA | Multi-Source Agreement | industry agreement for a form factor (MSA overview) |
| MTBF | Mean Time Between Failures | reliability figure, hours |
| MZM | Mach-Zehnder Modulator | external modulator (silicon photonics, coherent) |
| NIC | Network Interface Card | server adapter |
| NOS | Network Operating System | switch software (NOS landscape) |
| NRZ | Non-Return-to-Zero | two-level modulation |
| NVMe-oF | NVMe over Fabrics | storage protocol (NVMe-oF) |
| OADM / ROADM | (Reconfigurable) Optical Add-Drop Multiplexer | WDM node |
| OIF | Optical Internetworking Forum | CEI, 400ZR, CMIS 5.x |
| OLT / ONU / ONT | Optical Line / Network Terminal / Unit | PON head-end and subscriber ends |
| OM1–OM5 / OS1–OS2 | Optical Multimode / Singlemode grades | ISO/IEC 11801 fibre classes |
| OMA | Optical Modulation Amplitude | P1 − P0, the modulated power |
| OSFP | Octal SFP | 8-lane form factor (OSFP) |
| OSNR | Optical Signal-to-Noise Ratio | dB in 0.1 nm, DWDM quality figure |
| OTDR | Optical Time-Domain Reflectometer | fibre fault locator |
| OTN | Optical Transport Network | ITU-T G.709 framing |
| OUI | Organizationally Unique Identifier | IEEE vendor ID in EEPROM (Vendor fields) |
P–R
| Abbr. | Expansion | Meaning |
|---|
| PAM4 | 4-level Pulse Amplitude Modulation | 2 bits per symbol |
| PCS / PMA / PMD | Physical Coding / Medium Attachment / Medium Dependent sublayers | IEEE physical layer stack |
| PFC / ECN | Priority Flow Control / Explicit Congestion Notification | lossless Ethernet (Lossless Ethernet) |
| PIC | Photonic Integrated Circuit | integrated optics chip |
| PIN | p-i-n photodiode | standard receiver |
| PLL | Phase-Locked Loop | clock circuit |
| PN / SN | Part Number / Serial Number | identity fields (Part numbering) |
| PON | Passive Optical Network | shared-fibre access network |
| PRBS | Pseudo-Random Binary Sequence | test pattern (PRBS31, PRBS13Q) |
| PSM4 | Parallel Single Mode 4-lane | 100G 500 m MSA |
| QSA | QSFP-to-SFP Adapter | run an SFP module in a QSFP port (Port types) |
| QSFP / QSFP-DD | Quad SFP / Double Density | 4- and 8-lane form factors |
| RDMA / RoCE | Remote Direct Memory Access / RDMA over Converged Ethernet | AI/storage transport |
| RIN | Relative Intensity Noise | laser noise figure |
| RMA | Return Merchandise Authorization | warranty return |
| RoHS | Restriction of Hazardous Substances | EU directive, label marking |
| ROSA / TOSA | Receiver / Transmitter Optical Sub-Assembly | optical front end (Components) |
| RS / RS0 / RS1 | Rate Select | pins/bits selecting rate (Rate select) |
| RS-FEC | Reed-Solomon FEC | RS(528,514) Clause 91/108, RS(544,514) KP4 |
| Rx / Tx | Receive / Transmit | — |
| RX_LOS | receiver loss of signal pin | hardware LOS output |
S
| Abbr. | Expansion | Meaning |
|---|
| SAN | Storage Area Network | FC or Ethernet storage fabric |
| SC | Subscriber Connector | 2.5 mm push-pull connector |
| SerDes | Serializer/Deserializer | high-speed lane transceiver in ASICs |
| SFF / SNIA | Small Form Factor committee / Storage Networking Industry Association | publishers of SFF-8xxx |
| SFI / SFI+ | SFP+ high-speed serial interface | electrical interface of SFP+ (SFF-8431) |
| SFP / SFP+ / SFP28 / SFP56 / SFP-DD | Small Form-factor Pluggable family | 1 / 10 / 25 / 50 / 100 Gb/s (Form factors) |
| SGMII | Serial Gigabit Media Independent Interface | 1G copper SFP electrical mode |
| SiPh | Silicon Photonics | CMOS-made optics |
| SMSR | Side-Mode Suppression Ratio | single-mode laser purity, dB |
| SNMP | Simple Network Management Protocol | monitoring (Monitoring) |
| SNR | Signal-to-Noise Ratio | — |
| SOA | Semiconductor Optical Amplifier | on-chip preamplifier |
| SONiC | Software for Open Networking in the Cloud | open NOS |
| SR / SR4 / SR8 | Short Reach | 850 nm multi-mode PMDs |
| SWDM | Short Wavelength Division Multiplexing | 4 wavelengths 850–940 nm on OM5 |
T–Z
| Abbr. | Expansion | Meaning |
|---|
| TDECQ | Transmitter and Dispersion Eye Closure Quaternary | PAM4 transmitter quality, dB |
| TDP | Transmitter Dispersion Penalty | NRZ transmitter penalty, dB |
| TEC | Thermo-Electric Cooler | Peltier element stabilising laser temperature |
| TIA | Trans-Impedance Amplifier / Telecommunications Industry Association | receiver amplifier / standards body (TIA-568) |
| TX_DISABLE / TX_FAULT | transmitter disable / fault pins | hardware control and status (SFP hardware) |
| UI | Unit Interval | one symbol period |
| UPC | Ultra Physical Contact | flat polish, blue connectors |
| USR | Ultra Short Reach | vendor 850 nm PMD, ~100 m on OM3 |
| VCSEL | Vertical-Cavity Surface-Emitting Laser | 850 nm multi-mode laser |
| VDM | Versatile Diagnostics Monitoring | CMIS advanced diagnostics (VDM) |
| VOA | Variable Optical Attenuator | adjustable attenuator |
| VRP / EOS / NX-OS / Junos | vendor NOS names | Huawei / Arista / Cisco / Juniper |
| WDM | Wavelength Division Multiplexing | many wavelengths on one fibre |
| XAUI / XGMII | 10 Gigabit AUI / Media Independent Interface | 10G chip interfaces |
| XFP | 10 Gigabit Small Form-factor Pluggable | legacy 10G module (XFP) |
| XG-PON / XGS-PON | 10-Gigabit (Symmetric) PON | ITU-T G.987 / G.9807 |
| XLAUI | 40 Gb/s AUI | 4 × 10G |
| ZR / ZR+ | — | 80 km PMD; coherent 400ZR/OpenZR+ (Coherent) |
In CodingBox
Most of these abbreviations appear verbatim on the Check screen — compliance codes, DDM flags, CMIS states, power classes. The glossary explains the concepts; this page decodes the letters.