Abbreviations A–Z · Reference · Optical transceivers & cables · Documentation · CodingBox
CodingBox Documentation

Abbreviations A–Z

Optics documentation is written in acronyms: a datasheet line reads "SFP28 SR, 850 nm VCSEL, RS-FEC, OMA −6 dBm, DDM per SFF-8472". This index expands the abbreviations you meet in datasheets, switch output and CodingBox screens, with one line of meaning and a link to the material that explains the concept. For definitions of concepts rather than expansions see the Glossary.

A–B

Abbr.ExpansionMeaning
A0h / A2htwo-wire addresses 0xA0 / 0xA2identity and diagnostics memory of SFP-class modules (Memory map)
AECActive Electrical Cablecopper cable with retimers/DSP in the plugs (Cable internals)
ACCActive Copper Cablecopper cable with linear amplifiers, no retiming
ANAuto-Negotiationspeed/FEC negotiation, IEEE 802.3 Clause 73 on DAC (FEC & AN)
AOCActive Optical Cablefibre cable with fixed transceivers at both ends
APCAngled Physical Contact8° angled connector polish, green (Connectors)
APDAvalanche Photodiodehigh-sensitivity receiver for long reach (Receivers)
ASEAmplified Spontaneous Emissionnoise generated by optical amplifiers (OSNR)
ASICApplication-Specific Integrated Circuitthe switch forwarding chip (Inside a switch)
AUIAttachment Unit Interfacechip-to-module electrical interface: XAUI, CAUI-4, 400GAUI-8…
AWGArrayed Waveguide Grating / American Wire GaugeDWDM mux technology / copper conductor gauge in DAC
BASE-R / BASE-X—IEEE PCS families: 64b/66b (R) and 8b/10b (X)
BERBit Error Ratioerrored bits ÷ transmitted bits (Units)
BiDiBidirectionalone-fibre link with two wavelengths (Wavelength bands)
BOSABidirectional Optical Sub-AssemblyTOSA + ROSA + filter in one package

C–D

Abbr.ExpansionMeaning
CAUI100 Gb/s AUICAUI-10 (10 × 10G), CAUI-4 (4 × 25G)
CC_BASE / CC_EXT / CC_DMIchecksumsEEPROM checksums per SFF-8472/8636 (Checksums)
CDBCommand Data BlockCMIS command mechanism (firmware upgrade etc.) (CMIS)
CDRClock and Data Recoveryretiming circuit (CDR)
CEICommon Electrical I/OOIF electrical interface specs (CEI-28G, -56G, -112G)
CFPC Form-factor Pluggable100G/coherent module family
CMISCommon Management Interface Specificationmanagement for QSFP-DD, OSFP and others
COBChip-on-Boarddie-on-PCB packaging (COB)
CPOCo-Packaged Opticsoptics integrated with the switch ASIC
CPRI / eCPRICommon Public Radio Interfacemobile fronthaul protocols (Fronthaul)
CR / CR4 / CR8copperIEEE PMD names for DAC (25GBASE-CR, 100GBASE-CR4)
CRCCyclic Redundancy Checkframe check; CRC errors = link errors
CWDMCoarse WDM20 nm grid, 18 channels (CWDM)
DACDirect Attach Cablepassive twinax copper cable
DCMDispersion Compensation Modulefibre spool or grating compensating chromatic dispersion
DDM / DOMDigital Diagnostics Monitoring / Digital Optical Monitoringlive temperature, voltage, bias, powers (DDM basics)
DFBDistributed Feedback lasersingle-mode laser for 1310/1550 nm (Lasers)
DMLDirectly Modulated Laserlaser whose current is modulated
DPData PathCMIS lane group with its state machine
DR / DR4 / DR8500 m PMDsingle-mode parallel 500 m PMDs
DSPDigital Signal ProcessorPAM4 and coherent signal processing (DSP)
DWDMDense WDM100/50 GHz grid (DWDM)

E–G

Abbr.ExpansionMeaning
EDFAErbium-Doped Fibre AmplifierC/L-band optical amplifier
EEPROMElectrically Erasable Programmable ROMmodule memory
EMLExternally Modulated LaserDFB + electro-absorption modulator
EPON / GPON / XGS-PONEthernet / Gigabit / 10G-symmetric PONPON generations (PON standards)
ER / ER4 / ER8Extended Reach40 km PMDs
ER (optical)Extinction RatioP1/P0 of the transmitter, dB
ESDElectrostatic Dischargehandling hazard for modules
FC / GFCFibre Channel / Gigabit FCstorage network (Fibre Channel)
FECForward Error CorrectionBASE-R (Fire code), RS-FEC (528/544)
FPFabry-Pérot lasermulti-mode laser for short SMF links
FR / FR4 / FR82 km PMDsingle-mode 2 km PMDs
FTTxFibre To The xhome/building/curb access
GBICGigabit Interface Converterfirst-generation 1G module (GBIC)
GAUIe.g. 400GAUI-8AUI at 400G with 8 lanes
GBdgigabaudsymbols per second (Units)

H–L

Abbr.ExpansionMeaning
HA / HW / LA / LWHigh Alarm / High Warning / Low Alarm / Low WarningDDM thresholds (Thresholds)
HBAHost Bus AdapterFC server adapter
HDR / NDR / XDRInfiniBand generations200 / 400 / 800 Gb/s (InfiniBand speeds)
I²C / TWIInter-Integrated Circuit / Two-Wire Interfacethe management bus (Two-wire interface)
IBInfiniBandHPC/AI interconnect
IECInternational Electrotechnical Commissionconnector, fibre, laser-safety standards (Standards map)
IEEE 802.3Ethernet working groupPMD, PCS, FEC standards
INF-8077iXFP MSA documentXFP management (XFP)
ITU-TInternational Telecommunication Union, Telecom sectorfibre (G.652), grids (G.694.x), PON (G.984/G.9807), OTN (G.709)
KR / KR4backplaneIEEE backplane PMDs; KP4 = RS(544,514) FEC
LCLucent Connectorthe standard duplex connector
LOLLoss of LockCDR cannot lock
LOSLoss of Signalreceiver sees no light
LPMode / LowPwrLow Power modemodule held at ≤ 1.5 W (Power & thermal)
LPOLinear Pluggable OpticsDSP-less module relying on host equalisation
LR / LR4 / LR8Long Reach10 km PMDs
LRMLong Reach Multimode10GBASE-LRM, 220 m on OM1/OM2
LWDM / LAN-WDMLAN Wavelength Division Multiplexing800 GHz grid around 1300 nm used by LR4/ER4
LW / SW / ELWLong / Short / Extended Long WaveFibre Channel optic types

M–O

Abbr.ExpansionMeaning
MACMedia Access ControlEthernet framing layer
MDIOManagement Data I/OPHY management bus (not used by modules)
MISManagement Interface SpecificationSFP-DD management (MIS)
MMF / SMFMulti-Mode / Single-Mode Fibre50/62.5 µm core vs 9 µm
ModPrsL / MOD_ABSModule Present (active low) / Module Absentpresence pin
MPO / MTPMulti-fibre Push-On / MTP® brand12/16/24-fibre connector
MSAMulti-Source Agreementindustry agreement for a form factor (MSA overview)
MTBFMean Time Between Failuresreliability figure, hours
MZMMach-Zehnder Modulatorexternal modulator (silicon photonics, coherent)
NICNetwork Interface Cardserver adapter
NOSNetwork Operating Systemswitch software (NOS landscape)
NRZNon-Return-to-Zerotwo-level modulation
NVMe-oFNVMe over Fabricsstorage protocol (NVMe-oF)
OADM / ROADM(Reconfigurable) Optical Add-Drop MultiplexerWDM node
OIFOptical Internetworking ForumCEI, 400ZR, CMIS 5.x
OLT / ONU / ONTOptical Line / Network Terminal / UnitPON head-end and subscriber ends
OM1–OM5 / OS1–OS2Optical Multimode / Singlemode gradesISO/IEC 11801 fibre classes
OMAOptical Modulation AmplitudeP1 − P0, the modulated power
OSFPOctal SFP8-lane form factor (OSFP)
OSNROptical Signal-to-Noise RatiodB in 0.1 nm, DWDM quality figure
OTDROptical Time-Domain Reflectometerfibre fault locator
OTNOptical Transport NetworkITU-T G.709 framing
OUIOrganizationally Unique IdentifierIEEE vendor ID in EEPROM (Vendor fields)

P–R

Abbr.ExpansionMeaning
PAM44-level Pulse Amplitude Modulation2 bits per symbol
PCS / PMA / PMDPhysical Coding / Medium Attachment / Medium Dependent sublayersIEEE physical layer stack
PFC / ECNPriority Flow Control / Explicit Congestion Notificationlossless Ethernet (Lossless Ethernet)
PICPhotonic Integrated Circuitintegrated optics chip
PINp-i-n photodiodestandard receiver
PLLPhase-Locked Loopclock circuit
PN / SNPart Number / Serial Numberidentity fields (Part numbering)
PONPassive Optical Networkshared-fibre access network
PRBSPseudo-Random Binary Sequencetest pattern (PRBS31, PRBS13Q)
PSM4Parallel Single Mode 4-lane100G 500 m MSA
QSAQSFP-to-SFP Adapterrun an SFP module in a QSFP port (Port types)
QSFP / QSFP-DDQuad SFP / Double Density4- and 8-lane form factors
RDMA / RoCERemote Direct Memory Access / RDMA over Converged EthernetAI/storage transport
RINRelative Intensity Noiselaser noise figure
RMAReturn Merchandise Authorizationwarranty return
RoHSRestriction of Hazardous SubstancesEU directive, label marking
ROSA / TOSAReceiver / Transmitter Optical Sub-Assemblyoptical front end (Components)
RS / RS0 / RS1Rate Selectpins/bits selecting rate (Rate select)
RS-FECReed-Solomon FECRS(528,514) Clause 91/108, RS(544,514) KP4
Rx / TxReceive / Transmit—
RX_LOSreceiver loss of signal pinhardware LOS output

S

Abbr.ExpansionMeaning
SANStorage Area NetworkFC or Ethernet storage fabric
SCSubscriber Connector2.5 mm push-pull connector
SerDesSerializer/Deserializerhigh-speed lane transceiver in ASICs
SFF / SNIASmall Form Factor committee / Storage Networking Industry Associationpublishers of SFF-8xxx
SFI / SFI+SFP+ high-speed serial interfaceelectrical interface of SFP+ (SFF-8431)
SFP / SFP+ / SFP28 / SFP56 / SFP-DDSmall Form-factor Pluggable family1 / 10 / 25 / 50 / 100 Gb/s (Form factors)
SGMIISerial Gigabit Media Independent Interface1G copper SFP electrical mode
SiPhSilicon PhotonicsCMOS-made optics
SMSRSide-Mode Suppression Ratiosingle-mode laser purity, dB
SNMPSimple Network Management Protocolmonitoring (Monitoring)
SNRSignal-to-Noise Ratio—
SOASemiconductor Optical Amplifieron-chip preamplifier
SONiCSoftware for Open Networking in the Cloudopen NOS
SR / SR4 / SR8Short Reach850 nm multi-mode PMDs
SWDMShort Wavelength Division Multiplexing4 wavelengths 850–940 nm on OM5

T–Z

Abbr.ExpansionMeaning
TDECQTransmitter and Dispersion Eye Closure QuaternaryPAM4 transmitter quality, dB
TDPTransmitter Dispersion PenaltyNRZ transmitter penalty, dB
TECThermo-Electric CoolerPeltier element stabilising laser temperature
TIATrans-Impedance Amplifier / Telecommunications Industry Associationreceiver amplifier / standards body (TIA-568)
TX_DISABLE / TX_FAULTtransmitter disable / fault pinshardware control and status (SFP hardware)
UIUnit Intervalone symbol period
UPCUltra Physical Contactflat polish, blue connectors
USRUltra Short Reachvendor 850 nm PMD, ~100 m on OM3
VCSELVertical-Cavity Surface-Emitting Laser850 nm multi-mode laser
VDMVersatile Diagnostics MonitoringCMIS advanced diagnostics (VDM)
VOAVariable Optical Attenuatoradjustable attenuator
VRP / EOS / NX-OS / Junosvendor NOS namesHuawei / Arista / Cisco / Juniper
WDMWavelength Division Multiplexingmany wavelengths on one fibre
XAUI / XGMII10 Gigabit AUI / Media Independent Interface10G chip interfaces
XFP10 Gigabit Small Form-factor Pluggablelegacy 10G module (XFP)
XG-PON / XGS-PON10-Gigabit (Symmetric) PONITU-T G.987 / G.9807
XLAUI40 Gb/s AUI4 × 10G
ZR / ZR+—80 km PMD; coherent 400ZR/OpenZR+ (Coherent)

In CodingBox

Most of these abbreviations appear verbatim on the Check screen — compliance codes, DDM flags, CMIS states, power classes. The glossary explains the concepts; this page decodes the letters.


If you find an inaccuracy or error in this material, select the relevant fragment and press Ctrl+Enter to .