NICs with optical ports: an overview · Network interface cards · Network cards and switches · Documentation · CodingBox
CodingBox Documentation

NICs with optical ports: an overview

The other end of every server link is a network interface card (NIC), and it plays the same game as the switch — cages, SerDes lanes, a management bus to the module, a policy about which modules it accepts — with two differences: the policy lives in a driver, not a network OS, and the bottleneck is often the PCIe bus, not the port. This section covers NICs with SFP/QSFP-class cages: the families and vendors, how ports relate to PCIe, transceiver compatibility and its driver-level overrides, the tools that read a module from the server side, and the programmable adapters (SmartNICs, DPUs) that blur the line between card and switch.

Server path: CPU, PCIe, NIC controller and driver, cage, module or DAC, switch port

What a NIC is, in optics terms

ElementOn a switchOn a NIC
Cages24–64 per box1–4 per card (1–2 typical)
SerDesforwarding ASICNIC controller ASIC (Intel E810, Broadcom BCM57508, Nvidia ConnectX-7…)
Module managementNOS over I²C mux and CPLDdriver/firmware over the controller's I²C
PolicyNOS whitelist (How each NOS validates a module)driver/firmware whitelist (Optics compatibility on NICs)
Speed/FEC configCLIethtool, vendor tools, BIOS/UEFI, OS device manager (Tools)
Backhaulfabric ASICPCIe lanes to the CPU (Ports & PCIe)
Power3.3 V per cage from the chassisPCIe slot (25–75 W) plus auxiliary connector on high-end cards

Form factors of the card

Card typeWherePorts
PCIe add-in card (half-height half-length, full-height)any server slot1–2 × SFP28/QSFP28, 1–2 × QSFP56/QSFP112/QSFP-DD/OSFP
OCP NIC 3.0 (SFF / LFF mezzanine)OCP slot at the rear of the serversame cages, front-accessible, hot-swap on some chassis
LOM / embeddedon the motherboardusually RJ45; SFP+ on some
Mezzanine / bladeblade serversconnects to blade chassis switch, no cages
SmartNIC / DPUPCIe or OCP2 × 100/200/400G, own Arm cores (SmartNICs & DPUs)

Families and vendors

VendorFamilies (optical-port models)SpeedsCagesDriver (Linux)
IntelX520 / X710 / XXV710 / E810 / E83010G / 10G / 25G / 25–100G / 200GSFP+, SFP28, QSFP28, QSFP56ixgbe, i40e, ice, idpf
Nvidia (Mellanox)ConnectX-4 Lx / -5 / -6 Dx / -6 Lx / -7 / -8 SuperNIC25G / 100G / 100–200G / 25–50G / 200–400G / 800GSFP28, QSFP28, QSFP56, QSFP112, OSFPmlx5_core
BroadcomNetXtreme-E BCM5741x / 5750x (P225, P425, P2100, P1400GD)25G / 100–200G / 400GSFP28, QSFP56, QSFP-DDbnxt_en
Marvell (QLogic)FastLinQ 41000 / 4500010–25G / 100GSFP28, QSFP28qede
AMD (Solarflare, Pensando)X2522 / X3522; Pensando DSC10–25G; 100–200GSFP28; QSFP56sfc; ionic
ChelsioT610–100GSFP28, QSFP28cxgb4
OthersSilicom, Napatech (FPGA), Xilinx/AMD Alveo, Netronome10–100Gmixed—

Speeds per card model are fixed by controller and cages; "25G capable" means 10G and 25G, rarely 1G (Ports & PCIe).

What the NIC needs from a module

  • Compliance codes for a speed the controller supports at that cage.
  • Identity the driver accepts — Intel families are the strict ones (Optics compatibility on NICs).
  • FEC/AN behaviour the driver can match: DAC at 25G+ requires Clause 73 AN on both ends; optics need forced speed and matching FEC (FEC & AN).
  • Power class within the card's cage budget — most NICs allow QSFP28 class 4 (3.5 W) and QSFP-DD up to 12–15 W; check for ZR/tunable modules (Power & consumption).
  • Cooling: server airflow is front-to-back through the card; modules on rear-facing cards sit in exhaust air (Temperature grades).

Typical roles and their optics

RoleNICLink
General virtualisation host2 × 25G SFP28DAC to ToR (Roles & topologies)
Storage / NVMe-oF2 × 100G QSFP28DAC/AOC, RoCE with PFC (Lossless Ethernet)
GPU server4–8 × 400G OSFP/QSFP112 (one per GPU)AOC/DR4 to rail leaves (Cabling an AI cluster)
HPCInfiniBand HCA 1–2 × NDR/XDRDAC/AOC (IB cables)
Edge / branch2 × 10G SFP+LR to a campus core
Management / OOB1G RJ45 or SFP—

Further reading

In CodingBox

A module that a NIC rejects is diagnosed the same way as one a switch rejects: read the identity and compliance codes on the bench, compare with the driver's list, code if the policy demands it (Check transceiver, Vendor lock).


If you find an inaccuracy or error in this material, select the relevant fragment and press Ctrl+Enter to .