Specification revisions & version bytes · Specifications & standards · Optical transceivers & cables · Documentation · CodingBox
CodingBox Documentation

Specification revisions & version bytes

Specifications are living documents. A module declares which revision its memory map follows, and a host parses the map according to the revision it knows. Most of the time the two agree well enough; when they do not, a byte gets read as something it is not. This page lists the version bytes, how to decode them, and — roughly — what each generation added, so that you can tell whether a field you are looking at even exists for the module in front of you.

Where the version is declared

FamilyByteEncoding
SFF-8472 (SFP)A0h byte 94enumerated code (table below)
SFF-8636 (QSFP)byte 1enumerated code (table below)
CMISbyte 1major nibble . minor nibble (50h = 5.0)
MIS (SFP-DD)byte 1as CMIS
INF-8077i (XFP)nonethe identifier 06h implies INF-8077i rev 4.x

SFF-8472 — byte 94

ValueRevisionNotable additions, roughly
00hnot specifiedpre-diagnostic modules; identity only
01h9.3first digital diagnostics: A2h thresholds, monitors, flags
02h9.5clarifications, optional laser temperature / TEC monitors
03h10.2SFP+ era: rate select, linear receiver option, byte 93 enhanced options
04h10.4soft rate select per SFF-8431, power level 2, application select per SFF-8079
05h11.010G copper (DAC) coding — cable technology bits, attenuation in 60–61
06h11.3extended options, tunable transmitter option, 16GFC speed codes
07h11.4paged A2h memory (byte 64 bit 4), SFF-8690 tunable page 02h
08h12.0byte 36 extended specification compliance via SFF-8024; 25G/100G-era codes
09h12.4power level 3 (2.0 W), FC speed 2 in byte 62, PAM4 encoding code, alignment with SFF-8024

Rule of thumb: a module claiming 08h or 09h must have byte 36 meaningful (or zero) and the ×250 Mb/s rate in byte 66 when byte 12 = FFh; a module claiming 03h or below has no byte 36 semantics at all — hosts ignore it.

SFF-8636 — byte 1

ValueMap followsNotable additions
00hnot specified (SFF-8436 rev 4.8 or earlier)original QSFP+ map
01hSFF-8436 rev 4.8 or earlier—
02hSFF-8436 rev 4.8 with bytes 186–189 per SFF-8636wavelength and tolerance fields
03hSFF-8636 rev 1.3 or earlierfirst SFF-8636
04hrev 1.4—
05hrev 1.5—
06hrev 2.0QSFP28 / 100G: byte 192 extended compliance, power classes 5–7, CDR control and LOL flags
07hrev 2.5, 2.6, 2.7pages 20h–21h, Tx-disable fast mode, more Table 4-4 codes
08hrev 2.8, 2.9, 2.10power class 8 and byte 107 max power, 200G (QSFP56) codes, PAM4 encoding

Hosts that predate rev 2.0 will not look at byte 192 — a 100G module in a 40G-era switch is "unknown" for that reason alone, whatever the vendor block says.

CMIS — byte 1

ValueVersionNotable changes
30h3.0 (2018, QSFP-DD MSA)first common model: lower/upper pages, applications, module and data-path state machines, CDB
40h4.0 (2019)staged control sets, VDM pages 20h–2Fh, extended application descriptors, clearer durations
41h4.1corrections and clarifications
50h5.0 (2021, OIF)banks up to 32 lanes, refined data-path and lane-flag model, expanded VDM observables, diagnostic pages 13h–14h
51h–53h5.1, 5.2, 5.3incremental: additional VDM types, coherent (ZR) monitoring hooks, firmware-management refinements

A CMIS 5.x module in a host that implements 4.0 usually works for the basic flow (state machine, application select) but the host will not read newer VDM pages; a 3.0-only host may fail to bring up a 5.x module at all — CMIS issues. MIS versions track CMIS: MIS.

Compatibility rules

  • Newer module, older host — unknown codes decode as unknown; a higher byte 94 / byte 1 value is normally tolerated. Problems start when the host needs a field that only exists in the new revision (byte 192, applications).
  • Older module, newer host — fine; hosts keep backward parsing.
  • Claimed revision inconsistent with content — the real trap. Declaring 12.x with an empty byte 66 while byte 12 = FFh gives a host "0 Gb/s"; declaring rev 2.0+ with garbage in byte 192 gives unknown type. When coding, set the revision byte to match the fields you actually use.
  • SFF-8024 has no version byte in the module; the host's table revision decides which codes it can name.

Other documents and their cadence

DocumentCurrent generationNotes
SFF-8024rev 4.x, revised several times a yearnew identifiers, connectors and interface IDs land here first
INF-8077irev 4.5 (2005)XFP; stable, no further revisions expected — XFP
SFF-8690 / SFF-TA-10041.xtunable maps — Tunable maps
SFF-8079 / SFF-80891.xrate/application select — Rate select
Hardware specs (SFF-8431, SFF-8679, QSFP-DD HW, OSFP)see catalogSFP, QSFP hardware families