Dual Small Form-factor Pluggable (DSFP) puts two electrical lanes into a module with the mechanical dimensions of an SFP. With 2 × 50G PAM4 that is 100 Gb/s per port — the same goal as SFP-DD, reached by a different route: DSFP keeps a single row of contacts and adds pins to it, where SFP-DD adds a second row.

Key facts

Lanes × rate2 × 25G (NRZ) or 2 × 50G (PAM4)
Total50G / 100G; 2 × 100G (200G) planned by the MSA
SizeSFP mechanical dimensions, one row of contacts (22 pins instead of 20)
Identifier1Bh in SFF-8024
ManagementDSFP MIS — an abridged, CMIS-derived memory map
Applications5G and mobile infrastructure (fronthaul), 100G server adapters and AOC

Specifications

  • DSFP MSA Module Hardware Specification, Rev 1.0 (September 2018) — electrical, mechanical and thermal requirements for the module and the host: connector, cage, power and hardware I/O. Founding members: Amphenol, Finisar, Huawei, Lumentum, Molex, NEC, TE Connectivity and Yamaichi.
  • DSFP MIS — the management interface: an abridged version of CMIS, in the same family as the SFP-DD MIS.

Management interface

DSFP does not use the SFF-8472 two-address model of SFP. Like other CMIS-derived interfaces it has lower memory that is always accessible, paged upper memory and per-lane monitoring and control, cut down to two lanes. The identifier byte 1Bh tells the host — and CodingBox — which layout to apply.

Compatibility notes

  • The MSA keeps the SFP mechanical dimensions and aims at interoperation with existing SFP modules and cables. The second lane uses additional and reassigned contacts, so whether a given DSFP port accepts ordinary SFP/SFP28 modules depends on the host design — check the equipment documentation.
  • DSFP and SFP-DD are not interchangeable: they solve the same problem with different connectors and different management specifications.
  • DSFP is found mainly in wireless (5G) equipment and in some 100G network adapters; in switches and data centres SFP-DD and QSFP28 are more common for 100G.

In CodingBox

CodingBox recognises DSFP modules by the identifier 1Bh and decodes them with the CMIS-derived layout — identity, per-lane diagnostics and configuration pages — rather than the SFF-8472 map used for single-lane SFP modules.