Symptom index: where to start · Common problems & solutions · Optical transceivers & cables · Documentation · CodingBox
CodingBox Documentation

Symptom index: where to start

You have a symptom, not a diagnosis. Find the row that matches what you see, run the first checks, and follow the link to the detailed material. Every row assumes the diagnostic ladder as the baseline: levels → clean → swap → OTDR.

SymptomFirst checksLikely causesRead
Port down, module shows unsupported / invalid / Mod_Invhost log, identity on the benchvendor lock; identity or compliance codes the host rejectsVendor lock, No link checklist
Port down, Rx −40 dBm / LOS on both endsis Tx enabled? fibre continuity?fibre cut, Tx disabled by host, Tx/Rx crossed, wrong BiDi pair, wrong wavelength for the muxNo link checklist, Physical mismatches
Port down, Rx and Tx levels fineFEC and speed on both ends; AN on DACFEC mismatch, rate/breakout config, SGMII vs 1000BASE-X, CDR at wrong rateSpeed & rate, FEC & link training
Port down, Rx very high (> −3 dBm) on a short linklong-reach optic on a short span?receiver overloadPhysical mismatches
Works in one direction / LOS on one end onlycompare Rx on both endsdirty connector or weak laser on the failing side; polarityDDM levels, Physical mismatches
Link flaps up/downlevels, CRC counters, connectorscontamination, marginal budget, thermal throttlingLink flapping
400G/800G module recognised but never ready, stuck LowPwrCMIS module state, power class vs porthandshake / firmware / power classCMIS issues, Power & thermal
DAC does not link, optic in the same port doesAN/link training, cable length, identityAN disabled, unsupported cable, too long for the hostCopper & DAC, Speed & rate
SymptomFirst checksLikely causesRead
CRC / input errors climbingRx level vs baseline; FEC corrected counters; cleandirt, marginal budget, dispersion at 10G+ on long CWDMLink flapping, DDM levels
Slow throughput on a multi-lane link, no alarmsper-lane Rx/biasone degraded lane hidden by LACPFailures, Per-lane diagnostics
Works at 25G, dead at 10G (or 100G ok, 4×25G breakout not)rate codes, CDR bypass, host breakout configCDR range, module not breakout-capable, missing extended compliance codeSpeed & rate, CDR
Absurd DDM values (0 °C, +10 dBm, 0.00 V)byte 92 calibration bitsexternal calibration not applied, zeroed constantsCalibration
Tx power identical across a batchcompare modulesconstant Tx written to memoryDDM levels
Module hot, port disables it, "power exceeds" logpower class byte vs port rating; airflowclass mismatch, thermal shutdownPower & thermal
Everything fine for a year, then sudden failuresTx bias trend, batchlaser ageing, bad batch, heatFailures
Modules died after a switch firmware upgradehost release notes; identitystricter identity checks; clones failing authenticationVendor lock, Failures

On the bench (programmer / CodingBox)

SymptomFirst checksLikely causesRead
Module not detected on the programmerseating, form-factor adapter, power-up timenot seated, wrong cradle, module in LowPwrEEPROM read/write errors
Reads return FFh / 00h or garbageaddress (A0h/A2h/page), bus speedI²C NACK, wrong page, bus too fastEEPROM read/write errors
WRITE FAILpassword, WP type, clock speedprotected module, hardware WP, timingWrite-protection types, EEPROM recoding
Write "succeeds" but reverts after power cyclemodule typetemporary storage needs a save commandWrite-protection types
Host rejects module after editchecksumsstale CC_BASE / CC_EXT / CC_DMIMemory map

Access networks

SymptomFirst checksLikely causesRead
ONU does not register on the OLTserial / LOID, PON standard, ONU Rxwhitelist, wrong wavelength plan (GPON vs XGS-PON), Rx out of classPON problems
ONU shows LOSSC/APC cleanliness, splitter, polishdirt, UPC in an APC plant, fibrePON problems

If nothing matches

Work the no-link checklist top to bottom, then read the module on the bench with CodingBox: the Check transceiver screen tells you what the module claims to be, and DDM what it is actually doing.


If you find an inaccuracy or error in this material, select the relevant fragment and press Ctrl+Enter to .